9 - 57
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-
5 Mod
bu
s Com
m
u
n
icat
ion
Regi
ster Nu
m
b
er
List
9
9-5-
4 Group
A
Register
List
31DBh
31DAh
PID1 derivative gain 1
AH-63
R/W
0 to 10000
0.01(s)
31DCh
31DBh
PID proportional gain 2
AH-64
R/W
0 to 1000
0.1
31DDh
31DCh
PID integral time constant 2
AH-65
R/W
0 to 36000
0.1(s)
31Deh
31DDh
PID1 derivative gain 2
AH-66
R/W
0 to 10000
0.01(s)
31DFh
31DEh
PID1 gain change time
AH-67
R/W
0 to 10000
1(ms)
31E2h
31E1h
PID feed-forward selection
AH-70
R/W
00 (Disabled)
01 Ai1 terminal input
02 Ai2 terminal input
03 Ai3 terminal input
04 (Reserved)
05 (Reserved)
06 (Reserved)
-
31E3h
31E2h
PID1 output range
AH-71
R/W
0 to 10000
0.01(%)
31E4h
31E3h
PID1 Deviation over level
AH-72
R/W
0 to 10000
0.01(%)
31E5h
31E4h
PID1 Feedback compare sig-
nal turn-off level
AH-73
R/W
0 to 10000
0.01(%)
31E6h
31E5h
PID1 Feedback compare sig-
nal turn-on level
AH-74
R/W
0 to 10000
0.01(%)
31E7h
31E6h
PID soft start function enable
AH-75
R/W
00: Disabled
01: Enabled
-
31E8h
31E7h
PID soft start target level
AH-76
R/W
0 to 10000
0.01(%)
31Eah
31E9h
Acceleration time setting for
PID soft start function
AH-78
(HIGH)
R/W
0 to 360000
0.01(s)
31Ebh
31EAh
AH-79
(LOW)
R/W
31Ech
31EBh
PID soft start time
AH-80
R/W
0 to 60000
0.01(s)
31Edh
31ECh
PID soft start error detection
enable
AH-81
R/W
00: Disabled
01: Enabled: error output
02: Enabled: warning
-
31Eeh
31EDh
PID soft start error detection
level
AH-82
R/W
0 to 10000
0.01(%)
31F1h
31F0h
PID sleep trigger selection
AH-85
R/W
00: Disabled
01: Low output
02: [SLEP] terminal
-
31F2h
31F1h
PID sleep start level
AH-86
R/W
0 to 59000
0.01(Hz)
31F3h
31F2h
PID sleep active time
AH-87
R/W
0 to 10000
0.01(s)
31F4h
31F3h
Setpoint boost before PID
sleep enable
AH-88
R/W
00: Disabled
01: Enabled
-
31F5h
31F4h
Setpoint boost time
AH-89
R/W
0 to 10000
0.01(s)
31F6h
31F5h
Setpoint boost value
AH-90
R/W
0 to 10000
0.01(%)
31F7h
31F6h
Minimum RUN time befor PID
sleep
AH-91
R/W
0 to 10000
0.01(s)
31F8h
31F7h
Minimum active time of PID
sleep
AH-92
R/W
0 to 10000
0.01(s)
31F9h
31F8h
PID sleep trigger selection
AH-93
R/W
01: Deviation amount
02: Low feedback
03: ([WAKE] terminal
-
31Fah
31F9h
PID wake start level
AH-94
R/W
0 to 10000
0.01(%)
31FBh
31FAh
PID wake start time
AH-95
R/W
0 to 10000
0.01(s)
31FCh
31FBh
PID wake start deviation
value
AH-96
R/W
0 to 10000
0.01(%)
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......