9 - 61
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-
5 Mod
bu
s Com
m
u
n
icat
ion
Regi
ster Nu
m
b
er
List
9
9-5-
4 Group
A
Register
List
3234h
3233h
Input source selection of Pro-
cess data for PID4
AJ-52
R/W
00: Disabled
01: Ai1 terminal input
02: Ai2 terminal input
03: Ai3 terminal input
04: (Reserved)
05: (Reserved)
06: (Reserved)
07: Parameter setting
08: RS 485
09: Option 1
10: Option 2
11: Option 3
12: Pulse string input: Inverter
13: Pulse string input: Option
-
3235h
3234h
PID4 proportional gain
AJ-53
R/W
0 to 1000
0.1
3236h
3235h
PID4 integral time constant
AJ-54
R/W
0 to 36000
0.1(s)
3237h
3236h
PID4 derivative gain
AJ-55
R/W
0 to 10000
0.01(s)
3238h
3237h
PID4 output range
AJ-56
R/W
0 to 10000
0.01(%)
3239h
3238h
PID4 Deviation over level
AJ-57
R/W
0 to 10000
0.01(%)
323Ah
3239h
PID4 Feedback compare sig-
nal turn-off level
AJ-58
R/W
0 to 10000
0.01(%)
323Bh
323Ah
PID4 Feedback compare sig-
nal turn-on level
AJ-59
R/W
0 to 10000
0.01(%)
55F1h
55F0h
Main speed input source
selection, 2nd-motor
AA201
R/W
same as AA101
-
55F2h
55F1h
Sub speed input source
selection, 2nd-motor
AA202
R/W
same as AA102
-
55F4h
55F3h
Sub speed setting, 2nd-motor AA204
R/W
same as AA104
0.01(Hz)
55F5h
55F4h
Calculation symbol selection
for Speed reference,
2nd-motor
AA205
R/W
same as AA105
-
55F6h
55F5h
Add frequency setting,
2nd-motor
AA206
(HIGH)
R/W
same as AA106
0.01(Hz)
55F7h
55F6h
AA207
(LOW)
R/W
55FBh
55FAh
Run-command input source
selection, 2nd-motor
AA211
R/W
same as AA111
-
55FEh
55FDh
RUN-direction restriction,
2nd-motor
AA214
R/W
same as AA114
-
55FFh
55FEh
STOP mode selection,
2nd-motor
AA215
R/W
same as AA115
-
5605h
5604h
Control mode selection,
2nd-motor
AA221
R/W
Same as AA121, except 12
-
5607h
5606h
Vector control mode
selection, 2nd-motor
AA223
R/W
same as AA123
-
565Eh
565Dh
Multispeed-0 setting,
2nd-motor
Ab210
R/W
0 to 59000
0.01(Hz)
56C7h
56C6h
Select method to switch to
Accel2/Decel2 Profile,
2nd-motor
AC215
R/W
same as AC115
-
56C8h
56C7h
Accel1 to Accel2 Frequency
transition point, 2nd-motor
AC216
R/W
same as AC116
0.01(Hz)
56C9h
56C8h
Decel1 to Decel2 Frequency
transition point, 2nd-motor
AC217
R/W
same as AC117
0.01(Hz)
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......