8 - 107
8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8
-4 Co
n
tr
o
l Fu
n
ction
8
8-4
-8 Orientation Contr
ol
Precautions for Correct Use
• Do not set the orientation speed setting to a high frequency value because the inverter decel-
erates and completes positioning within 2 rotations. Decelerating to stop causes a rapid
movement and gives a large impact on the equipment. The overvoltage protection may
cause a trip.
• Set the orientation stop position by dividing one rotation to 4095 (0 to 4095) in the forward
rotation direction starting the reference point. (4096 division regardless of the number of
pulses for the encoder.)
• When ORT terminal with the orientation control is turned OFF during motor operation, the
motor is decelerated/stopped and the output is cut off. When the motor is operated again,
turn the operation command OFF.
The reference point is where the pulse is input between EZP-EZN and the stop target posi-
tion is located in a layout shown in the diagram to the left from the viewpoint of the motor axis
load. (For a positive phase connection)
Do not start the positioning process until the output frequency reaches the orientation speed
setting.
Adjusting the stop position at the positioning operation
Parameter
Adjustment of Stop Position at the Positioning Control
Occurrence
Workaround Examples
Stop position is short
Position shortens
• Adjust by increasing [AE-64] by 5%.
or
• Adjust by increasing [AE-65] by 5%.
Stop position is short
Position shortens
• Adjust by decreasing [AE-64] by 5%.
or
• Adjust by decreasing [AE-65] by 5%.
Item
Function
Code
Data/
Data Range
Description
Default
data
Deceleration stop dis-
tance calculation Gain
[AE-64]
50.00 to
200.00(%)
Adjust against the stop distance.
100.00
Deceleration stop dis-
tance calculation Bias
[AE-65]
0.00 to
655.35(%)
Adjust the output frequency for the position-
ing operation.
0.00
0
1024
3072
2048
Position of the Z pulse
Reference point
When looking at the
motor shaft from the
motor axis load
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......