How the inverter returns to the normal operation varies depending on the setting of the DC brak-
ing/edge or level selection [AF107].
When “00” is specified for [AF107], the inverter returns to the normal operation after [AF106] DC brak-
ing time has elapsed. (Ex.7)
When [AF107]=01: The inverter starts acceleration when the frequency command exceeds [AF103]+2
Hz. (Ex.8)
Precautions for Correct Use
• If the function of the DC braking with frequency command is enabled, [DB] (input terminal
030) will be disabled.
• If the function of the DC braking with frequency command is enabled, the setting of [AF102]
will be disabled and DC braking with [AF102]=00 will operate.
Edge mode: [AF107]=00
Level mode: [AF107]=01
(Ex.7)
(Ex.8)
Operation
command FW
Frequency
command
[AF103]
ON
AF106
[AF103]
Output
frequency
[AF103]
ON
[AF103]
Operation
command
FW
Frequency
command
Output
frequency
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......