3 - 35
3 Operation
High-function General-purpose Inverter RX2 Series User’s Manual
3-8 Param
eter F
unc
tion
3
3-
8-2 L
imiting
Displaye
d Parameter
s
If a function is not selected, parameters related to the function are hidden.
For more information about the display condition, see the table below.
The * mark in the table is replaced by 1 or 2. (1 represents first and 2 represents second.)
(a) IM control parameters
Display condition: AA121 ≤ 10 or AA221 ≤ 10
[UA-10]=01: Function-specific Display
Parameter
Name
Hb*02
* selection of the IM motor capacity
Hb*03
* selection of the IM motor pole number
Hb*04
* IM base frequency
Hb*05
* IM maximum frequency
Hb*06
* IM motor rated voltage
Hb*08
* IM motor rated current
Hb*10
* IM motor constant R1
Hb*12
* IM motor constant R2
Hb*14
* IM motor constant L
Hb*16
* IM motor constant Io
Hb*18
* IM motor constant J
Hb*30
* minimum frequency
Hb*31
* reduced voltage start time
Hb*40
* selection of operation mode for manual torque boost
Hb*41
* volume of manual torque boost
Hb*42
* break point of manual torque boost
Hb*45
* selection of energy-saving operation
Hb*46
* energy-saving response/accuracy adjustment
Hb*50
* free V/f frequency 1
Hb*51
* free V/f voltage 1
Hb*52
* free V/f frequency 2
Hb*53
* free V/f voltage 2
Hb*54
* free V/f frequency 3
Hb*55
* free V/f voltage 3
Hb*56
* free V/f frequency 4
Hb*57
* free V/f voltage 4
Hb*58
* free V/f frequency 5
Hb*59
* free V/f voltage 5
Hb*60
* free V/f frequency 6
Hb*61
* free V/f voltage 6
Hb*62
* free V/f frequency 7
Hb*63
* free V/f voltage 7
Hb*70
* slip compensation P gain with sensor
Hb*71
* slip compensation I gain with sensor
Hb*80
* output voltage gain
HC*01
* voltage compensation gain of automatic torque boost
HC*02
* slip compensation gain of automatic torque boost
HC*10
* 0th speed range limiter (IM-0Hz-SLV)
HC*11
* amount of boost at the start (IM-SLV, IM-CLV)
HC*12
* amount of boost at the start (IM-0Hz-SLV)
HC*13
* selection of whether a secondary-resistance correction is to be conducted (IM-SLV,
IM-0Hz-SLV,IM-CLV)
HC*14
* selection of reversal prevention (IM-SLV, IM-0Hz-SLV, IM-CLV)
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......