5 - 21
5 Monitor
High-function General-purpose Inverter RX2 Series User’s Manual
5-
12 Brakin
g
R
esisto
r Load
Rat
io Mo
nito
r
5
5-12 Braking Resistor Load Ratio Monitor
Display the use rate of braking resistor circuit (BRD).
Precautions for Correct Use
• A setting is required for a braking resistor circuit (BRD) to operate.
For details, see
8-2-5 Regenerative Braking Function
• The breaking resistor overload error [E006] is generated when the displayed rate exceeds
the Dynamic brake usage rate [bA-60].
Parameter
Item
Parameter
Data
Description
BRD load factor monitor
[dA-41]
0.00 to 100.00 (%)
Displays the load ratio of braking resis-
tor.
Dynamic brake usage rate
[bA-60]
0.0 to 100.0 (%)
Sets the maximum use rate of braking
resistor.
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......