Appendices C Table of Parameters
C - 58
High-function General-purpose Inverter RX2 Series User’s Manual
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial value
Note
Hb102
-
Async.Motor capacity setting,
1st-motor
0.01 to 160.00 (kW)
*1
Hb105
-
Async.Motor Maximum fre-
quency setting, 1st-motor
10.00 to 590.00 (Hz)
50.00
*2
Hb106
-
Async.Motor rated voltage,
1st-motor
1 to 1000 (V)
200 V class: 230
400 V class: 400
*2
460 (*FUF)
Hb108
-
Async.Motor rated current,
1st-motor
0.01 to 10000.00 (A)
*1
Hb110
-
Async.Motor constant R1,
1st-motor
0.000001 to 1000.000000 (Ω)
*1
Hb112
-
Async.Motor constant R2,
1st-motor
0.000001 to 1000.000000 (Ω)
*1
Hb114
-
Async.Motor constant L,
1st-motor
0.000001 to 1000.000000 (mH)
*1
Hb116
-
Async.Motor constant Io,
1st-motor
0.01 to 10000.00 (A)
*1
Hb118
-
Async.Motor constant J,
1st-motor
0.00001 to 10000.00000 (kgm
2
)
*1
Hb130
-
Minimum frequency adjust-
ment, 1st-motor
0.10 to 10.00 (Hz)
0.50
Hb131
○
Reduced voltage start time set-
ting, 1st-motor
0 to 2000 (ms)
36
Hb140
-
Manual torque boost opera-
tional mode selection, 1st-motor
00 (Disabled)/
01 (Always enabled)/
02 (Enabled only for forward revolution)/
03 (Enabled only for reverse revolution)
01
Hb141
○
Manual torque boost value,
1st-motor
0.0 to 20.0 (%)
0.0
Hb142
○
Manual torque boost Peak
speed, 1st-motor
0.0 to 50.0 (%)
0.0
Hb145
-
Eco drive enable, 1st-motor
00 (Disabled)/01 (Enabled)
00
Hb146
○
Eco drive response adjustment,
1st-motor
0.0 to 100.0(%)
50.0
Hb150
-
Free-V/f frequency 1 setting,
1st-motor
0.00 to [Hb152] (Hz)
0.00
Hb151
-
Free-V/f Voltage 1 setting,
1st-motor
0.0 to 1000.0 (V)
0.0
Hb152
-
Free-V/f frequency 2 setting,
1st-motor
[Hb150] to [Hb154] (Hz)
0.00
Hb153
-
Free-V/f Voltage 2 setting,
1st-motor
0.0 to 1000.0 (V)
0.0
Hb154
-
Free-V/f frequency 3 setting,
1st-motor
[Hb152] to [Hb156] (Hz)
0.00
Hb155
-
Free-V/f Voltage 3 setting,
1st-motor
0.0 to 1000.0 (V)
0.0
Hb156
-
Free-V/f frequency 4 setting,
1st-motor
[Hb154] to [Hb158] (Hz)
0.00
Hb157
-
Free-V/f Voltage 4 setting,
1st-motor
0.0 to 1000.0 (V)
0.0
Hb158
-
Free-V/f frequency 5 setting,
1st-motor
[Hb156] to [Hb160] (Hz)
0.00
Hb159
-
Free-V/f Voltage 5 setting,
1st-motor
0.0 to 1000.0 (V)
0.0
Hb160
-
Free-V/f frequency 6 setting,
1st-motor
[Hb158] to [Hb162] (Hz)
0.00
Hb161
-
Free-V/f Voltage 6 setting,
1st-motor
0.0 to 1000.0 (V)
0.0
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......