C - 33
Appendices C Table of Parameters
High-function General-purpose Inverter RX2 Series User’s Manual
C-
3 Paramet
er List
C
AJ-27
-
Input source selection of
Set-point for PID3
00 (None)/01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/05 (Reserved)/
06 (Reserved)/07 (Parameter setting)/08 (RS 485)/
09 (Option 1)/10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)
07
AJ-30
○
Set-point setting for PID3
-100.00 to 100.00 (%)
*2
0.00
AJ-32
-
Input source selection of Pro-
cess data for PID3
00 (None)/01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/05 (Reserved)/
06 (Reserved)/07 (Parameter setting)/08 (RS 485)/
09 (Option 1)/10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)
01
AJ-33
○
PID3 proportional gain
0.0 to 100.0
1.0
AJ-34
○
PID3 integral time constant
0.00 to 3600.0 (s)
1.0
AJ-35
○
PID3 derivative gain
0.0 to 100.00 (s)
0.00
AJ-36
○
PID3 output range
0.00 to 100.00 (%)
0.00
AJ-37
○
PID3 deviation over level
0.00 to 100.00 (%)
3.00
AJ-38
○
PID3 feedback compare signal
turn-OFF level
0.00 to 100.00 (%)
100.00
AJ-39
○
PID3 feedback compare signal
turn-ON level
0.00 to 100.00 (%)
0.00
AJ-41
-
PID4 enable
00 (Disabled)/
01 (Enabled Without reverse output)/
02 (Enabled With reverse output)
00
AJ-42
-
PID4 deviation inverse
00 (Disabled)/01 (Enabled)
00
AJ-43
-
PID4 unit selection
See
on page C-70 at the end of Appendices
C
01
AJ-44
○
PID4 scale adjustment (0%)
-10000 to 10000
0
AJ-45
○
PID4 scale adjustment (100%)
-10000 to 10000
10000
AJ-46
○
PID4 scale adjustment (point
position)
0 to 4
2
AJ-47
-
Input source selection of
Set-point for PID4
00 (None)/01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/05 (Reserved)/
06 (Reserved)/07 (Parameter setting)/08 (RS 485)/
09 (Option 1)/10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)
07
AJ-50
○
Set-point setting for PID4
-100.00 to 100.00 (%)
*3
0.00
AJ-52
-
Input source selection of Pro-
cess data for PID4
00 (None)/01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/05 (Reserved)/
06 (Reserved)/07 (Parameter setting)/08 (RS 485)/
09 (Option 1)/10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)
01
AJ-53
○
PID4 proportional gain
0.0 to 100.0
1.0
AJ-54
○
PID4 integral time constant
0.00 to 3600.0 (s)
1.0
AJ-55
○
PID4 derivative gain
0.0 to 100.00 (s)
0.00
AJ-56
○
PID4 output range
0.00 to 100.00 (%)
0.00
AJ-57
○
PID4 deviation over level
0.00 to 100.00 (%)
3.00
AJ-58
○
PID4 feedback compare signal
turn-OFF level
0.00 to 100.00 (%)
100.00
AJ-59
○
PID4 feedback compare signal
turn-ON level
0.00 to 100.00 (%)
0.00
*1. Data range differs depending on [AJ-04] to [AJ-06].
*2. Data range differs depending on [AJ-24] to [AJ-26].
*3. Data range differs depending on [AJ-44] to [AJ-46].
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......