9 - 29
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-
5 Mod
bu
s Com
m
u
n
icat
ion
Regi
ster Nu
m
b
er
List
9
9-5-
2 Group d
Register
List
03E9h
03E8h
Trip monitor 1 Factor
dE-11
R
1 to 255
1
03EAh
03E9h
Trip monitor 1 Output fre-
quency
-59000 to 59000
0.01(Hz)
03EBh
03EAh
(with sign)
03ECh
03EBh
Trip monitor 1 Output cur-
rent
0 to 65535
0.01(A)
03EDh
03ECh
Trip monitor 1 P-N DC volt-
age
0 to 10000
0.1(Vdc)
03EEh
03EDh
Trip monitor 1 Inverter state
0 to 8
*5
1
03EFh
03EEh
Trip monitor 1 LAD state
0 to 5
*5
1
03F0h
03EFh
Trip monitor 1 INV control
mode
0 to 11
*5
1
03F1h
03F0h
Trip monitor 1 Limit state
0 to 6
*5
1
03F2h
03F1h
Trip monitor 1 Special state
0 to 6
*5
1
03F4h
03F3h
Trip monitor 1 RUN time
0 to 1000000
1(hr)
03F5h
03F4h
03F6h
03F5h
Trip monitor 1 Power ON
time
0 to 1000000
1(hr)
03F7h
03F6h
03F8h
03F7h
Trip monitor 1 Absolute time
(year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
1
03F9h
03F8h
Trip monitor 1 Absolute time
(day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
1
03FAh
03F9h
Trip monitor 1 Absolute time
(hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
1
03FDh
03FCh
Trip monitor 2 Factor
dE-12
R
1 to 255
1
03FEh
03FDh
Trip monitor 2 Output fre-
quency
-59000 to 59000
0.01(Hz)
03FFh
03FEh
(with sign)
0400h
03FFh
Trip monitor 2 Output cur-
rent
0 to 65535
0.01(A)
0401h
0400h
Trip monitor 2 P-N DC volt-
age
0 to 10000
0.1(Vdc)
0402h
0401h
Trip monitor 2 Inverter state
0 to 8
*5
1
0403h
0402h
Trip monitor 2 LAD state
0 to 5
*5
1
0404h
0403h
Trip monitor 2 INV control
mode
0 to 11
*5
1
0405h
0404h
Trip monitor 2 Limit state
0 to 6
*5
1
0406h
0405h
Trip monitor 2 Special state
0 to 6
*5
1
0408h
0407h
Trip monitor 2 RUN time
0 to 1000000
1(hr)
0409h
0408h
040Ah
0409h
Trip monitor 2 Power ON
time
0 to 1000000
1(hr)
040Bh
040Ah
040Ch
040Bh
Trip monitor 2 Absolute time
(year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
040Dh
040Ch
Trip monitor 2 Absolute time
(day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
040Eh
040Dh
Trip monitor 2 Absolute time
(hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......