8 Applied Settings
8 - 158
High-function General-purpose Inverter RX2 Series User’s Manual
You can set a response time per input terminal.
This function is effective for removing noise caused by chattering, etc.
If stable terminal input is not secured due to chattering, increase the set value. However, increasing the
set value results in a slow response.
For the correspondence between input terminals and parameters, please refer to the table shown on
the below.
Parameter
(Ex.) Operation of Input terminal 1
8-10-3 Input Terminal Response Time
Input terminal
Response time
1
[CA-41]
2
[CA-42]
3
[CA-43]
4
[CA-44]
5
[CA-45]
6
[CA-46]
7
[CA-47]
8
[CA-48]
9
[CA-49]
A
[CA-50]
B
[CA-51]
Item
Parameter
Data
Description
Input terminal
response time
[CA-41]/[CA-42]/[CA-43]/[CA-44]/
[CA-45]/[CA-46]/[CC-47]/[CA-48]/
[CA-49]/[CA-50]/[CA-51]
0 to 400(ms)
*1
*1. When setting to 0, the operation starts about at 1 ms.
Sets a response time.
[CA-41]
[CA-41]
ON
OFF
OFF
ON
Operation of
input terminal
Operation of
internal function
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......