8 - 19
8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8-1
P
ID Con
trol
8
8-1
-3 PID Soft-sta
rt Fu
nction
PID gain is time for PID1 gain to switch [AH-67] and switches continuously.
Each gain selected for PIDs can be checked by respective monitors [db-61] to [db-63].
In the case of using this function, enable PID control and set 01 to the [AH-75] PID soft-start function
selection.
It will move to PID control automatically after the elapse of the time set in [AH-80].
It accelerates to soft-start target level [AH-76] after start of soft-start.
Parameter
8-1-3
PID Soft-start Function
Item
Parameter
Data
Description
Default
data
PID soft start function
enable
[AH-75]
00
Disable
00
01
Enable
PID soft start target
level
[AH-76]
0.00 to
100.00(%)
It is a target value of the soft-start range with
the maximum frequency as 100%.
100
Acceleration time set-
ting for PID soft start
function
[AH-78]
0.00 to
3600.00(s)
Sets acceleration time at the time of
soft-start.
30.00
PID soft start time
[AH-80]
0.00 to
600.00(s)
Is soft-start operation time.
0.00
ON
[AH-67]
[AH-67]
Gain 2
Gain 1
Input signal [PRO]
ON
PID operation
Soft-start
target level [AH-76]
Output Frequency
Soft-start time [AH-80]
Time
Acceleration according to [AH-78]
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......