C - 55
Appendices C Table of Parameters
High-function General-purpose Inverter RX2 Series User’s Manual
C-
3 Paramet
er List
C
CE-48
○
Window comparator for [Ai3]
hysteresis width
0 to 10 (%)
0
CE-50
○
Operation level at [Ai1] discon-
nection
0 to 100 (%)
0
CE-51
○
Operation level selection at [Ai1]
disconnection
00 (Disabled)/01 (Enabled: out of range)
02 (Enabled: within the range)
00
CE-52
○
Operation level at [Ai2] discon-
nection
0 to 100(%)
0
CE-53
○
Operation level selection at [Ai2]
disconnection
00 (Disabled)/01 (Enabled: out of range)/
02 (Enabled: within the range)
00
CE-54
○
Operation level at [Ai3] discon-
nection
-100 to 100(%)
0
CE-55
○
Operation level selection at [Ai3]
disconnection
00 (Disabled)/01 (Enabled: out of range)/
02 (Enabled: within the range)
00
CE201
○
Low current signal output mode
selection, 2nd-motor
00 (During acceleration/deceleration, at constant
speed)/
01 (Only at constant speed)
01
CE202
○
Low current detection level 1,
2nd-motor
(0.0 to 2.0)
× Inverter rated current
*1
1.0
× Inverter rated
current
CE203
○
Low current detection level 2,
2nd-motor
(0.0 to 2.0)
× Inverter rated current
*1
1.0
× Inverter rated
current
CE205
○
Over current signal output mode
selection, 2nd-motor
00 (During acceleration/deceleration, at constant
speed)/
01 (Only at constant speed)
01
CE206
○
Over current detection level 1,
2nd-motor
(0.0 to 2.0)
× Inverter rated current
*1
1.0
× Inverter rated
current
CE207
○
Over current detection level 2,
2nd-motor
(0.0 to 2.0)
× Inverter rated current
*1
1.0
× Inverter rated
current
CE220
○
Over torque level (Forward driv-
ing), 2nd-motor
0.0 to 500.0 (%)
100.0
CE221
○
Over torque level (Reverse
regenerative), 2nd-motor
0.0 to 500.0 (%)
100.0
CE222
○
Over torque level (Reverse driv-
ing), 2nd-motor
0.0 to 500.0 (%)
100.0
CE223
○
Over torque level (Forward
regenerative), 2nd motor
0.0 to 500.0 (%)
100.0
*1. On the parameter about the current and the voltage, the figures and the units to be handled vary in the setting path.
1) Operator or CX-Drive: 0.1 A or 0.1 V (When CX-Drive is operated, set [CF-11] Resister data selection to 00 (A,V). When the data of
[CF-11] Resister data selection is not set to 00 (A,V), it is not set or displayed correctly.)
2) Modbus: The current and the voltage vary, depending on the setting of Resister data selection [CF-11].
When [CF-11] Resister data selection is set to 00 (A,V), 0.1 A, 0.1 V
When [CF-11] Resister data selection is set to 01 (%), 0.01% (Rated ratio)
3) Drive programming: 0.01% (Rated ratio)
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial value
Note
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......