DIRECT STATION SELECTION (DSS) CONSOLE (CONT’D)
OPERATING PROCEDURE
To display station Busy Out (
BYO
) status:
1. Depress the Function Mode key on the DSS CONSOLE assigned for BUSY OUT STATUS dis-
play. An LED associated with the
BYO
key lights.
2. When stations are currently in the BUSY OUT state, their associated LED will light green.
3. Depress the same Function Mode key to return to DSS mode, if desired.
SERVICE CONDITIONS
1. If the system is initialized (Reset), the Console Function Mode will return to DSS.
2. The BUSY OUT STATUS of a station cannot be set or cancelled from a BUSY OUT STATUS CON-
SOLE.
3. Refer to the DSS CONSOLE and the UNIFORM CALL DISTRIBUTION Features and Specifications
for more details.
DO NOT DISTURB CONSOLE
GENERAL DESCRIPTION
This feature allows a DSS CONSOLE associated with a D
term
to be used as a DO NOT DISTURB
(DND) CONSOLE. This feature is activated by the use of a Function Mode key on a DSS CONSOLE.
DND set status for each station is indicated by a green LED associated with each key. In addition, the
D
term
user can set/cancel the DND status of other stations using the DND CONSOLE.
STATION APPLICATION
All stations with a DSS CONSOLE
OPERATING PROCEDURE
To set and cancel DO NOT DISTURB (DND):
1. Depress the
DND
key. When stations are currently in DND their associated LED will light green.
2. Depress the Function Mode key: an LED associated with the Function Mode key will light red.
3. Depress the desired
DSS
key(s) to set or cancel. A lit LED indicates DND is set.
4. Depress the
DND
key again to return to DSS mode, if desired.
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...