![NEC NEAX 2000 Скачать руководство пользователя страница 266](http://html.mh-extra.com/html/nec/neax-2000/neax-2000_programming-manual_251364266.webp)
D
term
– 246 –
A2234-10
HARDWARE REQUIRED
D
term
and DLC card
DESCRIPTION
DATA
Allocate the memory area for Speed Call-
ing-Station to each station.
The same memory area must be assigned
on CM73 and CM94, to provide BLF func-
tion on D
term
line key.
(1)
(2)
X-XXXXXXXX: My Line No.
W XX 0 ZZ
W : 0-3 (Basic):
1000-Slot Memory Block No.
XX: 00-99: Start of 10-Slot Memory
Block No.
ZZ : 01-10: Number of 10-Slot Memory
Blocks
NOTE:
1000-Slot Memory Block number 4-9 (6000 Memory Parcels) can not be used to
provide BLF function on D
term
line key.
Assign Speed Calling-Station keys on
each D
term
.
For the key number and the last two digits
of the second data, assign the same num-
ber as follows.
1st Data
2ndData
XXXXXXXX, 01
F1101
XXXXXXXX, 02
F1102
XXXXXXXX, 03
F1103
XXXXXXXX, 16
F1116
•
(1)
(2)
Y=00
My Line No. +
+ Key No.
F11XX
XX: 00-99: Speed Calling-Station
00-99
NOTE 1:
The initial setting of key layout
is for 16 Line/Trunk/Feature
keys (key No. 01-16).
When using key No. 17-24,
data setting of CM12 Y=24,
2nd data=0 is required.
NOTE 2:
A station user should set the
required extension number to
the line key on D
term
.
Specify the type of busy indication on the
BLF of the D
term
line key as station base or
extension base.
(1)
(2)
269
0
: Station base
1
: Extension base
CM94
END
CM90
C
..
.
..
.
,
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...