![NEC NEAX 2000 Скачать руководство пользователя страница 264](http://html.mh-extra.com/html/nec/neax-2000/neax-2000_programming-manual_251364264.webp)
D
term
– 244 –
A2234-10
DESCRIPTION
DATA
Allocate the memory area for Speed Call-
ing-Station to each station.
The same memory area must be assigned
on CM73 and CM94.
The memory area for storing one called
number of Speed Calling-Station is called
a “Memory Parcel”. An assembly of 10
Memory Parcels is called a “10-Slot Mem-
ory Block,” and one hundred 10-Slot Mem-
ory Blocks are called a “1000-Slot Memory
Block”.
(1)
(2)
X-XXXXXXXX: My Line No.
W XX Y ZZ
W : 0-3 (Basic):
1000-Slot Memory Block No.
NOTE
XX: 00-99: Memory Start Block No.
(10-Slot Memory Block)
Y : Facility for programming the dialed
number from the station
0/1: Effective/Ineffective
ZZ : 01-10: Number of 10-Slot Memory
Blocks
NOTE:
1000-Slot Memory Block No. 4-9 (6000 Memory Parcels) can not be used to pro-
vide BLF function on D
term
line key.
Example:
If the stored number intended is 10 for Station Number 300, 20 for Station Num-
ber 301, and 30 for Station Number 302, the memory areas assignment is as fol-
lows.
Memory Start
1000-Slot Memory
Block No. (10-Slot
Number of 10-Slot
Station No.
Block No.
Memory Block)
Memory Block
(1st Data)
(2nd Data: W)
(2nd Data: XX)
(2nd Data: ZZ)
300
0
00
01
301
0
01
02
302
0
03
03
303
0
06
01
CM73
A
B
0
~
3
4
1000-Slot
Memory Block
0
9
1
Memory Parcel
00
99
01
10-Slot
Memory Block
Basic 4000
Option 6000
~
9
Memory Parcels
Memory Parcels
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...