![NEC NEAX 2000 Скачать руководство пользователя страница 685](http://html.mh-extra.com/html/nec/neax-2000/neax-2000_programming-manual_251364685.webp)
GUEST/ADMINISTRATIVE SERVICE
– 665 –
A2653-10
GUEST/ADMINISTRATIVE SERVICE
PROGRAMMING
DESCRIPTION
DATA
Assign the tenant number to each guest
station and administrative station, respec-
tively. The different tenant number must be
assigned to guest and administrative sta-
tion.
•
(1)
(2)
Y=04
X-XXXX: Station No.
00-63: Tenant No.
Assign the Tenant number to each trunk.
•
(1)
(2)
Y=01
000-255: Trunk No.
00-63: Tenant No.
Assign the Numbering Plan Group number
to each tenant for guest and administrative
station.
(1)
(2)
00-63: Tenant No.
710-713: Numbering Plan Group 0-3
Assign required access codes for each
Numbering Plan Group.
To provide its own trunk route for each ten-
ant, assign the Tenant Block 00-23 to de-
sired trunk route access code.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A000-A097
801-808
A100-A152
100-163: Trunk Route 00-63
300-323: Tenant Block 00-23
When Tenant Block 00-23 is assigned by
CM20, assign the trunk route and tenant
number to the Tenant Block.
•
(1)
(2)
Y=00-23 Tenant Block 00-23
00-63: Tenant No.
100-163: Trunk Route 00-63
Specify the tenant to be handled by each
ATT Group.
•
(1)
(2)
Y=0-3 ATT Group 0-3 assigned by
CM60 Y=00
00-63: Tenant No.
0 : To be handled
1 : Not to be handled
CM30
CM29
CM20
START
CM12
A
CM62
CM23
INITIAL
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...