VARIABLE TIMING PARAMETERS (CONT’D)
SERVICE CONDITIONS (CONT’D)
7. Recall timing after station release for CALL TRANSFER - ALL CALLS:
a. Standard timing: 24 - 28 seconds
b. Variable timing: 4 - 120 seconds (4-second increments)
8. PERIODIC TIME INDICATION TONE interval:
a. Standard timing: 180 - 184 seconds
b. Variable timing: 32 - 724 seconds (60-second increments)
9. Automatic cancel time for unanswered external paging calls:
a. Standard timing: 300 seconds
b. Variable timing: 60-900 seconds (60-second increments)
10. Reorder Tone timeout to enter LINE LOCKOUT state and OFF-HOOK ALARM:
a. Standard timing: 28-32 seconds
b. Variable timing: 4 to 32 seconds (4-second increments)
11. Ringing duration of AUTOMATIC WAKE UP call (TIMED REMINDER):
a. Standard timing: 28-32 seconds
b. Variable timing: 4 - 32 seconds (4-second increments)
12. Single digit dialing timer (Timing Start):
a. Standard timing: 4-5 seconds
b. Variable timing: 2-8 seconds (1-second increments)
13. Maximum UNIFORM CALL DISTRIBUTION (UCD) call waiting time before answer or abandon-
ment for PEG COUNT:
a. Standard timing: 32-36 seconds
b. Variable timing: 4-120 seconds (4-second increments)
14. Automatic recall of STATION CAMP-ON:
a. Standard timing: 24-32seconds
b. Variable timing: 8-128 seconds (8-second increments)
15. Timing before unanswered AUTOMATED ATTENDANT call forwards:
a. Standard timing: 32-36 seconds
b. Variable timing: 4-120 seconds (4-second increments)
16. Interval time between attempts for TIMED QUEUE - D
term
:
a. Standard timing: 60 - 64 seconds
b. Variable timing: 4-124 seconds (4-second increments)
17. Duration of call by TIMED QUEUE - D
term
:
a. Standard timing: 30 seconds
b. Variable timing: 8-124 seconds (4-second increments)
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...