![NEC NEAX 2000 Скачать руководство пользователя страница 541](http://html.mh-extra.com/html/nec/neax-2000/neax-2000_programming-manual_251364541.webp)
TIMED REMINDER
– 521 –
A2512-10
DESCRIPTION
DATA
•
(1)
(2)
Y=08
00-63: Tenant No.
00-63: Message No. assigned by
CM49 Y=00
Assign the Timed Reminder feature ac-
cess key to a D
term
, if required.
•
(1)
(2)
Y=00
My Line No. +
+ Key No.
F0024
Specify the timing for Timed Reminder
start.
(1)
(2)
228: Timed Reminder start timing
0 : At preset time
1 : Before 5 minutes of preset time
Specify the duration of a Timed Reminder
call.
•
(1)
(2)
Y=0
23
01-08: 4 sec.-32 sec.
(4 sec. increments)
If no data is set, the default setting is 28-32
sec.
Specify the duration of message replay for
Timed Reminder.
•
(1)
(2)
Y=0
52
01-99: 4 sec.-396 sec.
(4 sec. increments)
If no data is set, the default setting is 60-64
sec.
Specify the number of Timed Reminder
call attempts before abandonment.
(1)
(2)
03
01-15: Number of attempted Timed Re-
minder call
If no data is set, the default setting is 05.
Specify the maximum number of Timed
Reminder calls that can be set at the same
time.
(1)
(2)
04
01-32: Max. number of stations
If no data is set, the default setting is 16.
To record, replay, or delete a message, as-
sign the appropriate Digital Announce-
ment Trunk access code.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A100: Record
A101: Replay
A102: Delete
CM49
A
CM90
CM08
CM41
END
CM42
CM20
,
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...