![NEC NEAX 2000 Скачать руководство пользователя страница 560](http://html.mh-extra.com/html/nec/neax-2000/neax-2000_programming-manual_251364560.webp)
TRUNK TO TRUNK CONNECTION
– 540 –
A2536-10
TRUNK TO TRUNK CONNECTION
PROGRAMMING
DESCRIPTION
DATA
Assign the Service Restriction Class C to
each station.
•
(1)
(2)
Y=07
X-XXXXXXXX: My Line No.
00-15 : Service Restriction Class C
Provide the switch hook flash capability
during C.O. line connection in the Service
Restriction Class C assigned by CM12
Y=07.
•
(1)
(2)
Y=90, 91
00-15: Service Restriction Class C as-
signed by CM12 Y=07
1 : Allow
Specify the combination of trunk routes al-
lowing the Trunk to Trunk Connection.
•
(1)
(2)
Y=0
XX ZZ
XX: 00-63: Incoming trunk route
ZZ: 00-63: Outgoing trunk route
0 : Allow
1 : Restricted
Provide the system with Ring Transfer for
Call Transfer-All Calls to a trunk when a
station holds another station or trunk.
(1)
(2)
253
0: Available
Provide the system with forced release
when a tandem call duration passes a pre-
determined time.
(1)
(2)
029
0 : To disconnect
1 : To continue
Allow or restrict forced release of tandem
connection for the incoming trunk route.
This data is available when CM08>029 is
set to 0.
•
(1)
(2)
Y=119
00-63: Trunk Route No.
0 : Allow
1 : Restricted
Specify the forced release timing for tan-
dem call.
•
(1)
(2)
Y=0
54
01-06: 64 min.-224 min.
(32 min. increments)
If no data is set, the default setting is 96-128
min.
CM15
CM08
CM35
START
CM12
CM41
CM36
A
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...