STATION MESSAGE DETAIL RECORDING (SMDR)
PROGRAMMING
SMDR with AP00 Programming
– 488 –
A2486-10
DESCRIPTION
DATA
Specify the timing of SMDR valid call timer
(pseudo-answer timer).
•
(1)
(2)
Y=0
03
00-08: 8 sec.-40 sec.
(4 sec. increments)
If no data is set, the default setting is
20-24 sec.
Specify the contents of the detail call infor-
mation to be sent to the SMDR.
(1)
(2)
60
0 : Only the called party’s No. is sent
1 : Access Code is sent with the
called party’s No.
Specify the Advice of Charge (AOC).
[Australia Only]
(1)
(2)
176
0 : No
1 : Yes
Specify whether ISDN call charge informa-
tion is sent to the SMDR terminal.
[Australia Only]
(1)
(2)
68
0 : Not sent
1 : To send
Specify whether call start year and call
end year are sent to the SMDR terminal.
[Australia Only]
(1)
(2)
238
0 : Not sent
1 : To send
Specify the condition code 1/2 for Advice
of charge in SMDR NEAX2400 IMS For-
mat.
[Australia Only]
(1)
(2)
276
0 : Condition Code 1 is 1 cent unit.
Condition Code 2 is 0. 1 cent unit.
1 : Condition Code 1 is 0. 1 cent unit.
Condition Code 2 is 1 cent unit.
Specify the measured rate.
Use first data: 69 for dollar/franc, and use
first data: 70 for cent/centime.
By this setting, the call charge is calculat-
ed according to the message rate sent
from the network, and is sent to the SMDR
terminal (NEAX2400 IMS Format, charac-
ter 118-124) as AOC, when CMD000>68
is sent to “1”.
[Australia Only]
(1)
(2)
(1)
(2)
69 (dollar/franc)
00-99: 00-99 dollars/franc
70 (cent/centimes)
00-99: 00-99 cents/centimes
CMD000
CM42
CM41
A
B
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...