![NEC NEAX 2000 Скачать руководство пользователя страница 1173](http://html.mh-extra.com/html/nec/neax-2000/neax-2000_programming-manual_2513641173.webp)
ND-91285-001(E)
DECEMBER, 1999
Page 391
Revision 1.0
(1/3)
VARIABLE TIMING PARAMETERS
GENERAL DESCRIPTION
This feature gives the system the versatility to change timing duration using the MAINTENANCE
ADMINISTRATION TERMINAL (MAT) or the CUSTOMER ADMINISTRATION TERMINAL (CAT).
All timing parameters are set initially in the RESIDENT SYSTEM PROGRAM. These TIMING
PARAMETERs can be changed according to the customer’s requirements.
STATION APPLICATION
Not applicable.
OPERATING PROCEDURE
Refer to the Installation Procedure Manual/Feature Programming Manual for programming instructions.
SERVICE CONDITIONS
The Feature Programming Manual contains instructions on how to change the following timing durations:
1. Automatic Recall of ATTENDANT CAMP-ON and unanswered calls:
a. Standard timing: 31.2 - 33.6seconds
b. Variable timing: 2.4 - 124.8 seconds (2.4-second increments in 2.4 - 33.6 seconds
9.6-second increments in 38.4 - 124.8 seconds)
2. Elapsed time before CALL FORWARDING - DON’T ANSWER for incoming trunk calls or AUTO-
MATIC CHANGE OF NIGHT SERVICE activation:
a. Standard timing: 32 - 36 seconds
b. Variable timing: 4 - 120 seconds (4-second increments)
3. STATION MESSAGE DETAIL RECORDING (SMDR) valid call timer:
a. Standard timing: 20 - 24 seconds
b. Variable timing: 8 - 40 seconds
4. Disconnect recognition time for trunks:
a. Standard timing: 0.96 - 1.44 seconds
b. Variable timing: 0.48 - 6.72 seconds (0.48-second increments)
5. Recall timing for EXCLUSIVE HOLD - D
term
:
a. Standard timing: 236 - 240 seconds
b. Variable timing: 4 - 396 seconds (4-second increments)
6. Recall timing for NONEXCLUSIVE HOLD - D
term
and CALL PARK:
a. Standard timing: 60 - 64 seconds
b. Variable timing: 4 - 396 seconds (4-second increments)
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...