![NEC NEAX 2000 Скачать руководство пользователя страница 822](http://html.mh-extra.com/html/nec/neax-2000/neax-2000_programming-manual_251364822.webp)
ND-91285-001(E)
DECEMBER, 1999
Page 40
Revision 1.0
(1/2)
AUTOMATIC CAMP-ON
GENERAL DESCRIPTION
In a case where an incoming C.O. Line call, which has terminated to the desired station, if the desired
station is busy, the call is camped-on automatically. Under such a state, if the busy station becomes idle,
the station is automatically called out and is connected to the camped-on incoming C.O. Line call.
STATION APPLICATION
All stations
OPERATING PROCEDURE
No manual operation is required.
SERVICE CONDITIONS
1. For sending CAMP-ON tone, there are two patterns: one is to send the tone at an interval of 8 seconds,
and the other is to send the tone only once at the initial time. Either one of these patterns can be
selected by system base.
2. CAMP-ON cannot be set to the same station from plural trunks concurrently.
3. Because DIRECT IN TERMINATION calls can overflow, these calls can be directed to either; the
Attendant, TAS indication, or can be automatically Camped-On. All of which can be assigned by the
office data.
4. Relation with other services is as follows:
a. CALL BACK
CAMP-ON service can be set to a party which has set (or has been set with) CALL BACK
service.
CALL BACK service can be set to a party to which CAMP-ON service has been set.
In both of the above cases, re-ring of CAMP-ON has higher priority over CALL BACK.
b. OUTGOING TRUNK QUEUEING
CAMP-ON service can be set to a party which has set OG Queueing service.
OG Queueing service can be set from the party to which CAMP-ON service has been set.
In both of the above cases, re-ring CAMP-ON has higher priority over OG Queueing.
c. EXECUTIVE RIGHT OF WAY / BUSY VERIFICATION
CAMP-ON service can be set to the party engaging in a bridged call (three-way calling).
A bridge-in can be made in a case where CAMP-ON service has been set to the party to be
bridged in or to the call destination.
Содержание NEAX 2000
Страница 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Страница 95: ...BROKER S CALL 75 A2066 10 BROKER S CALL PROGRAMMING Refer to CALL HOLD and CALL HOLD Dterm page 95 ...
Страница 102: ...CALL BACK MULTIPLE ASSIGNMENT 82 A2076 10 CALL BACK MULTIPLE ASSIGNMENT PROGRAMMING Refer to CALL BACK page 80 ...
Страница 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Страница 272: ...EXECUTIVE RIGHT OF WAY EXECUTIVE RIGHT OF WAY Dterm 252 A2247 10 HARDWARE REQUIRED Dterm and DLC card if required ...
Страница 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Страница 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Страница 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Страница 496: ...STATION LINE STATUS DISPLAY 476 A2463 10 STATION LINE STATUS DISPLAY PROGRAMMING Refer to Maintenance Manual ...
Страница 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 757: ...ND 91285 001 E ISSUE 1 Model 100MX BUSINESS FEATURES AND SPECIFICATIONS DECEMBER 1999 NEC Corporation ...
Страница 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 1197: ......
Страница 1198: ......
Страница 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...