N
OTE
:
When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds
for the system to recognize the PSU and determine its status. The PSU redundancy
may not occur until discovery is complete. Wait until the new PSU is discovered and
enabled before you remove the other PSU. The PSU status indicator turns green to
signify that the PSU is functioning properly.
Removing a non-redundant cabled AC power supply unit
l
Follow the safety guidelines listed in
l
Follow the procedure listed in
Before working inside your system
.
l
Remove the air shroud
l
Disconnect the system from the electrical outlet.
l
Disconnect all the cables connected from the PSU to the system board.
l
If applicable, remove the expansion card riser.
Follow the below steps to remove a non-redundant cabled AC power supply unit :
1. Using a Phillips #2 screwdriver, remove the screw securing the PSU to the system.
2. Slide the PSU out of the PSU cage.
Installing a non-redundant cabled AC power supply unit
l
Follow the safety guidelines listed in
Follow the below steps to install a non-redundant cabled AC power supply unit :
1. Unpack the new power supply unit (PSU).
2. Slide the new PSU into the PSU cage until the PSU is fully seated.
3. Using a Phillips #2 screwdriver, replace the screw to secure the PSU to the system.
Installing and Removing System Components
Power supply units
93
GigaVUE-FM Hardware Appliance Guide for GFM-HW1-FM010 and GFM-HW1-FM001-HW