4. Hold the blue touch points and lift the internal PERC riser out of the system.
5. Turn the internal riser so that the PERC card is facing up.
6. Press the cable connector and disconnect the cable that is connected to the internal
PERC card
After removing the Internal PERC riser you can do the following :
1. Install the air shroud.
2. Follow the procedure listed in
After working inside your system
.
3. Install the internal PERC card.
Installing the Internal PERC Riser
N
OTE
:
The new generation PERC 11 H750, H350, and HBA350i adapters cannot be
mixed with the PERC H740P, H730P, H330, HBA330 adapters of the previous
generations in one system. For more information, see Cable routing.
l
Follow the safety guidelines listed in
Follow the below steps to install the Internal PERC Riser:
1. Connect the cable to the internal PERC card.
Installing and Removing System Components
Internal PERC riser
60