3. Connect the intrusion switch cable to the connector on the system board.
After installing the Intrusion Switch ensure the following:
1. Install internal PERC riser.
2. Follow the procedure listed in
After working inside your system
.
Drives
This describes the procedure to install and remove the Drives.
Removing a Drive Blank
l
Follow the safety guidelines listed in
l
If installed, remove the front bezel.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty
drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not
supported.
Follow the below steps to remove the Drive Blank:
1. Press the release button, and slide the drive blank out of the drive slot.
After removing the Drive Blank ensure the following:
1. Install a drive or Installing the hard drive backplane.
Installing a drive blank
l
Follow the safety guidelines listed in
l
If installed, remove the front bezel.
Installing and Removing System Components
Drives