773232AH
10-131
Using Navios Software
Analysis Menu
10
When drawing or modifying Regions the status bar divides into three areas of information. These
update as a region is modified:
•
The status bar shows Channel for X parameter
•
The total integral count of the region
•
The percentage of events currently within the region.
X Coordinate
The X Axis channel value is the coordinate of the cursor position given by a scaling factor. This
scaling factor depends on whether the Histogram parameter is using linear or logarithmic
amplification and whether you have calibrated that parameter or not.
If the parameter is linear and uncalibrated, the X channel varies between 0 - 255 or 0 - 1024
depending on the data source. If the parameter is logarithmic and uncalibrated, the value varies
between 0.1024 - 1024 and span four decades. For most other manufacturers, the data varies
between 1 - 10,000, spanning four decades also.
Integral
When you create a Region the status bar reflects the integral values given along the scale for that
parameter at the cursor position. That is, before the first marker is set.
If the cursor is on channel 10, the integral shows the count value of the populations at channel 10.
After first marker is set and as you move the mouse to either the left or right of this point, the
integral value continuously updates to reflect the summation of each channel between the Region
starting position and the current mouse position.
Multiple Linear Regions
This option sets multiple consecutive linear Regions on one display. When linear regions are created
using the Multiple Linear Regions option, gates are not created even though
is selected in Workspace Preferences. See:
.
Interactive Multi-Linear Region Editing
When a Region's position is changed, any Gates that use the Region are automatically updated and
each plot is redrawn to reflect the changes in the Gate. When the Region is deleted any Gate which
used the Region is also automatically deleted. When a Gate has been deleted, any plot that used the
deleted Gate is reset to Ungated. Allows you to resize an already created Region.
View / Modify Regions
Use this option to view/edit a Region's properties, Region points or to delete a Region that is no
longer required.
Содержание Navios
Страница 8: ...773232AH viii Safety Notice Safety Symbols ...
Страница 34: ...xxxiv Tables A 2 Code Related Specifications A 6 ...
Страница 38: ...773232AH xxxviii Introduction Graphics ...
Страница 44: ...773232AH 1 6 Use And Function Material Safety Data Sheets MSDS ...
Страница 72: ...773232AH 3 18 Operation Principles Plot Display ...
Страница 90: ...773232AH 4 18 Specifications Software Specifications 1 2 3 ...
Страница 140: ...773232AH 5 34 System Overview Using The System Help ...
Страница 154: ...773232AH 6 14 Daily Routine Cytometer Auto Startup ...
Страница 194: ...773232AH 8 16 Running Samples Data Review ...
Страница 412: ...773232AH 10 216 Using Navios Software Report Generator Error Log ...
Страница 446: ...773232AH 11 34 Cleaning Procedures Power The Cytometer Only On off ...
Страница 522: ...773232AH 13 30 Troubleshooting Cytometer Control Window Cannot Be Viewed ...
Страница 530: ...773232AH A 8 Bar code Specifications Checksum Algorithm ...
Страница 540: ...773232AH References 2 References ...
Страница 582: ...Index 36 Index ...
Страница 584: ...773232AH Warranty 2 Beckman Coulter Inc Customer End User License Agreement ...
Страница 585: ......