Using Navios Software
File Menu
Workspace Preferences - LMD File Name
Workspace Preferences - User Info
Workspace Preferences - Plot Display
Workspace Preferences - Gating
Workspace Preferences - Publish
Output Options
The Output actions occur automatically at the completion of the acquisition of each sample tube.
Check the appropriate options for the actions you wish to perform when acquiring data using the
Acquisition Manager. See also,
Workspace Preferences - Publish
NOTE
Save Protocol applies to any changes made to a protocol, whether acquiring or not. You cannot alter
the Save LMD default, as this is a mandatory setting. If a protocol name begins with Cleanse, the protocol
does not create a listmode file when the protocol is run.
Acquisition Manager
Auto Duplicate Previous Panel
adds a copy of the current panel into the Acquisition Manager at the
completion of the current panel, and is useful if you wish to run samples in Panel Mode but do not
wish to define a complete worklist in advance.
•
In Automatic mode, the software will duplicate the last panel each time it reaches the end of the
worklist and automatically begins acquisition on the first tube in that Panel.
•
Acquisition will stop when either the maximum 32 tubes have been acquired or when the
instrument attempts to acquire from a location which does not contain a tube.
•
Regardless of the manually entered numbering of the first Panel, all AutoDuplicated Panels will
be numbered consecutively, continuing from the last run test.
•
Sample ID1s will always be populated with the Run Number.
•
Sample ID2-4 will not be entered and consequently cannot be selected as part of the LMD
filename.
•
If the last acquired tube location was 32, the Panel will not be AutoDuplicated. The worklist will
NOT wrap around to tube location 1.
•
If there are insufficient available locations to insert a complete Panel without exceeding tube
location 32, the Panel will not be AutoDuplicated.
Содержание Navios
Страница 8: ...773232AH viii Safety Notice Safety Symbols ...
Страница 34: ...xxxiv Tables A 2 Code Related Specifications A 6 ...
Страница 38: ...773232AH xxxviii Introduction Graphics ...
Страница 44: ...773232AH 1 6 Use And Function Material Safety Data Sheets MSDS ...
Страница 72: ...773232AH 3 18 Operation Principles Plot Display ...
Страница 90: ...773232AH 4 18 Specifications Software Specifications 1 2 3 ...
Страница 140: ...773232AH 5 34 System Overview Using The System Help ...
Страница 154: ...773232AH 6 14 Daily Routine Cytometer Auto Startup ...
Страница 194: ...773232AH 8 16 Running Samples Data Review ...
Страница 412: ...773232AH 10 216 Using Navios Software Report Generator Error Log ...
Страница 446: ...773232AH 11 34 Cleaning Procedures Power The Cytometer Only On off ...
Страница 522: ...773232AH 13 30 Troubleshooting Cytometer Control Window Cannot Be Viewed ...
Страница 530: ...773232AH A 8 Bar code Specifications Checksum Algorithm ...
Страница 540: ...773232AH References 2 References ...
Страница 582: ...Index 36 Index ...
Страница 584: ...773232AH Warranty 2 Beckman Coulter Inc Customer End User License Agreement ...
Страница 585: ......