Specifications
Software Specifications
$PnV
Voltage of sensor associated with parameter n.
$PROJ
Project name (from Workspace Preferences)
$RUNNUMBER
(See $SMNO) System defined run number, that is, a number which is incremented
each time the flow cytometer is used to acquire data.
$SMNO
System defined run number, that is, a number which is incremented each time the
flow cytometer is used to acquire data.
$SRC
Sample Source (from Workspace preferences)
$SYS
BCI
$TOT
Total number of events acquired.
@ABSCALFACTOR
Defines the calibration factor of the beads used with this sample if Flow-Count or
similar absolute calibration particles are used.
@ACQTIME
Acquisition time from start to end of acquisition (excluding pause time).
@ACQUISITIONPROTOCOLOFFSET
Defines where in the LMD file the Runtime Protocol is stored, the value displayed is
number of bytes from start of file to the start of the protocol section.
@BARCODE
Barcode read from the sample loader or “No Read” if nothing is read.
@BASELINEOFFSET
Default is 'OFF' any other means ON, that is, this sample was acquired using baseline
offset.
@BLUELASERPOWER_END
Blue laser power at end of acquisition.
@BLUELASERPOWER_START
Blue laser power at start of acquisition.
@BLUELASERSHUTTER
Blue laser shutter status.
@BLUETARGETPOWER
Blue laser target power.
@BUILDNUMBER
Software build number.
@CAROUSEL
Carousel number read from the sample loader.
@CYTOLINKMULTIPLECLIENT
Indicates whether other Cytolink client was connected to CytoLink during acquisition
of the LMD file (“TRUE” or “FALSE”).
@CYTOMETERID
The unique ID given to the flow cytometer by the user, for example: the flow
cytometer serial number.
@Discriminator
Displays the discriminator detector and level. In the form: “Detector Name, Level”.
The Level value corresponds to the setting value displayed in the Cytometer Control
screen.
@ELAPSEDTIME
Total elapsed time from start to end of acquisition (including acquisition and pause
time).
@FILEGUID
Unique 128 bit number identifying this file, changed every time the file is saved.
@LOCATION
The address of the institute who owns the flow cytometer.
@PANEL
Name of the panel file used for acquisition of the sample.
@PnADDRESS
Mutliplexor address of parameter n.
@PnC
Calculation method for parameter n, 'ARITHMETIC' means use arithmetic method for
calculation. ‘GEOMETRIC’ means use of a geometric method for calculation. This
value may be overridden by analysis engine.
Table 4.1
FCS 2.0 Keyword Information
FCS 2.0 Keyword
Key value
Содержание Navios
Страница 8: ...773232AH viii Safety Notice Safety Symbols ...
Страница 34: ...xxxiv Tables A 2 Code Related Specifications A 6 ...
Страница 38: ...773232AH xxxviii Introduction Graphics ...
Страница 44: ...773232AH 1 6 Use And Function Material Safety Data Sheets MSDS ...
Страница 72: ...773232AH 3 18 Operation Principles Plot Display ...
Страница 90: ...773232AH 4 18 Specifications Software Specifications 1 2 3 ...
Страница 140: ...773232AH 5 34 System Overview Using The System Help ...
Страница 154: ...773232AH 6 14 Daily Routine Cytometer Auto Startup ...
Страница 194: ...773232AH 8 16 Running Samples Data Review ...
Страница 412: ...773232AH 10 216 Using Navios Software Report Generator Error Log ...
Страница 446: ...773232AH 11 34 Cleaning Procedures Power The Cytometer Only On off ...
Страница 522: ...773232AH 13 30 Troubleshooting Cytometer Control Window Cannot Be Viewed ...
Страница 530: ...773232AH A 8 Bar code Specifications Checksum Algorithm ...
Страница 540: ...773232AH References 2 References ...
Страница 582: ...Index 36 Index ...
Страница 584: ...773232AH Warranty 2 Beckman Coulter Inc Customer End User License Agreement ...
Страница 585: ......