Specifications
Software Specifications
4
Parameters
16 different signals, including Time and Ratio (derived parameter) can be acquired simultaneously
in logarithmic and linear modes, giving up to 32 acquisition parameters from a possible 62.
5 different signals available from each detector:
•
Integral linear
•
Integral logarithmic
•
Peak linear
•
Peak logarithmic
•
Time of Flight linear.
Regions
Up to 32 gates and 256 analysis regions are available for gating, analysis, and autogating per
protocol. Up to 8 of those regions can be used to create any one gate. The following types of regions
are available for gating and analysis:
•
Linear
•
Rectangular
•
Quadrant
•
Polygonal
•
Elliptical
•
Contour.
Listmode Analysis
The instrument can store up to 16 parameters including TIME, and RATIO as listmode data. The
amount of available random access memory (RAM) in the computer determines the maximum size
of a listmode file. See
Locked Protocols
User defined protocols can be locked or unlocked by a System Administrator and password
protected to prevent inadvertent modifications. The optional application software
(e.g. Navios tetra) uses locked protocols that cannot be unlocked by a System Administrator . The
following software screens are disabled when using locked protocols. You cannot make changes to
the locked features on these screens.
(QC product selection and export region statistics are not locked)
Содержание Navios
Страница 8: ...773232AH viii Safety Notice Safety Symbols ...
Страница 34: ...xxxiv Tables A 2 Code Related Specifications A 6 ...
Страница 38: ...773232AH xxxviii Introduction Graphics ...
Страница 44: ...773232AH 1 6 Use And Function Material Safety Data Sheets MSDS ...
Страница 72: ...773232AH 3 18 Operation Principles Plot Display ...
Страница 90: ...773232AH 4 18 Specifications Software Specifications 1 2 3 ...
Страница 140: ...773232AH 5 34 System Overview Using The System Help ...
Страница 154: ...773232AH 6 14 Daily Routine Cytometer Auto Startup ...
Страница 194: ...773232AH 8 16 Running Samples Data Review ...
Страница 412: ...773232AH 10 216 Using Navios Software Report Generator Error Log ...
Страница 446: ...773232AH 11 34 Cleaning Procedures Power The Cytometer Only On off ...
Страница 522: ...773232AH 13 30 Troubleshooting Cytometer Control Window Cannot Be Viewed ...
Страница 530: ...773232AH A 8 Bar code Specifications Checksum Algorithm ...
Страница 540: ...773232AH References 2 References ...
Страница 582: ...Index 36 Index ...
Страница 584: ...773232AH Warranty 2 Beckman Coulter Inc Customer End User License Agreement ...
Страница 585: ......