SmartPAC 2 with WPC 2000 Integration User Manual
1128600
Installation
2-95
9.
Check to see whether fault code F48 appears on the LED display.
•
If F48 displays, go to the next step.
•
If F48 does not display, check to see whether the “System air pressure” LED on the
WPC 2000 Main Processor board is unlit. If the LED is unlit, check the wiring of the
system air pressure switch input and correct any problems. Press both Run/Inch palm
buttons again. If F48 still does not display, call Wintriss Tech. Support.
10.
Apply system air pressure to the press.
11.
Check to see whether the “System air pressure” LED on the WPC 2000 Main Processor
board is lit. Clear the error code on the display by pressing RESET.
12.
Turn off the counterbalance air and bleed down the counterbalance air pressure.
13.
Press both Run/Inch palm buttons on the Operator Station at the same time. The ram
should not move, and the fault code associated with the input the counterbalance pressure
switch is connected to (normally, F54 for User 4 Input) should display.
•
If the ram does not move and the appropriate fault code appears, restore the
counterbalance air, press RESET, and go to the next step.
•
If the ram moves and/or the appropriate fault code does not display, check the wiring of
the counterbalance air pressure switch input, and correct any problems. Push both Run/
Inch palm buttons again. If the ram still moves and/or the appropriate fault code still
does not display, call Wintriss Tech. Support.
14.
Press the Emergency Stop button on the Operator Station.
•
If fault code F13 displays, go to the next applicable test.
•
If F13 does not display, contact Wintriss Tech. Support.
If the E-stop and Top-stop circuits are not connected according to the wiring shown in
Figure 2 at the end of the manual, the fault code that displays may be different. Call
Wintriss Tech. Support for assistance.
If the E-stop and Top-stop circuits are not connected according to the wiring shown in
Figure 2 at the end of the manual, the fault code that displays may be different. Call
Wintriss Tech. Support for assistance.
NOTICE
NOTICE
Summary of Contents for SmartPAC 2
Page 2: ......
Page 4: ......
Page 6: ......
Page 28: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual xxii Table of Contents ...
Page 44: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual 1 16 Introduction ...
Page 186: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual 3 26 Keyboard Displays Etc ...
Page 440: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual D 12 Updating SmartPAC 2 Firmware ...
Page 478: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual G 6 Replacing SmartPAC 2 PC Board ...
Page 548: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual GL 8 Glossary ...
Page 558: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual IN 10 Index ...
Page 560: ......
Page 562: ......
Page 564: ......
Page 566: ......
Page 568: ......
Page 570: ......
Page 572: ......
Page 574: ......
Page 576: ......
Page 577: ......
Page 578: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 579: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 580: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 581: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 582: ......
Page 583: ......
Page 584: ......
Page 585: ......
Page 586: ......
Page 587: ......
Page 588: ......
Page 589: ......
Page 590: ......
Page 591: ......
Page 592: ......
Page 593: ......
Page 594: ......
Page 595: ......
Page 596: ......
Page 597: ......
Page 598: ......
Page 599: ......
Page 600: ......
Page 601: ......
Page 602: ......
Page 603: ......
Page 604: ......