To perform the system static test, do the following, referring to Figure 2-41 for LED locations
and
, page 4-44 for instructions in how to access the Input Status screens:
1.
Turn off the system air and bleed down the system air pressure to less than 35 PSI.
2.
On the SmartPAC 2 front panel:
•
Turn the Program/Run key switch to RUN.
•
Turn the Stroke Select key switch of OFF.
•
Select TWO HAND on the Mode Select Menu (see page 6-40)
•
Turn the Stroke Select key switch to INCH.
3.
Check to see whether the Interrupted Stroke message flashes on the SmartPAC 2 display.
•
If the Interrupted Stroke message displays, go to the next step.
•
If the Interrupted Stroke message does not display, check to see whether the “INCH
SEL” item on the WPC Buttons and Switches Input Status screen is ON (see
Figure 4-26, page 4-45). If “INCH SEL” shows an OFF status, check the wiring of the
Stroke Select switch and correct any problems. If “INCH SEL” is still OFF, call
Wintriss Tech. Support.
4.
Press the Emergency Stop button on the Operator Station.
5.
Check to see whether fault code F13 appears on the SmartPAC 2 display.
•
If F13 displays, go to the next step.
•
If F13 does not display, check to see whether the “E-stop A input” and “E-stop B input”
LEDs on the WPC 2000 Main Processor board turn off when the Emergency Stop
button is pressed. If the two LEDs do not turn off, check the wiring of the E-stop A and
E-stop B input connections, and correct any problems. If the two LEDs still do not turn
off, call Wintriss Tech. Support.
6.
Turn on the press motor in forward rotation (if applicable).
7.
Check to see whether the “Motor forward” LED on the WPC 2000 Main Processor board
is lit.
•
If the “Motor forward” LED is lit, go to the next step.
•
If the “Motor forward” LED is unlit, check the wiring of the Motor Forward input
connection, and correct any problems. If the LED is still unlit, call Wintriss Tech.
Support.
8.
Press both Run/Inch palm buttons on the Operator Station at the same time.
RESET EMERGENCY-STOP BUTTON AFTER USE
The Emergency-stop button is not spring-loaded. You must pull it up to its original position
to reset the Emergency-stop (F13) fault.
NOTICE
Summary of Contents for SmartPAC 2
Page 2: ......
Page 4: ......
Page 6: ......
Page 28: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual xxii Table of Contents ...
Page 44: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual 1 16 Introduction ...
Page 186: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual 3 26 Keyboard Displays Etc ...
Page 440: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual D 12 Updating SmartPAC 2 Firmware ...
Page 478: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual G 6 Replacing SmartPAC 2 PC Board ...
Page 548: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual GL 8 Glossary ...
Page 558: ...1128600 SmartPAC 2 with WPC 2000 Integration User Manual IN 10 Index ...
Page 560: ......
Page 562: ......
Page 564: ......
Page 566: ......
Page 568: ......
Page 570: ......
Page 572: ......
Page 574: ......
Page 576: ......
Page 577: ......
Page 578: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 579: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 580: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 581: ...APPROVALS SCALE C SIZE TITLE SHEET OF DRAWING NUMBER REV ...
Page 582: ......
Page 583: ......
Page 584: ......
Page 585: ......
Page 586: ......
Page 587: ......
Page 588: ......
Page 589: ......
Page 590: ......
Page 591: ......
Page 592: ......
Page 593: ......
Page 594: ......
Page 595: ......
Page 596: ......
Page 597: ......
Page 598: ......
Page 599: ......
Page 600: ......
Page 601: ......
Page 602: ......
Page 603: ......
Page 604: ......