Target window
Right click on the target (ARPA or AIS) and select
Display in a window
from the list.
A floating window centered on the target and following automatically the target is displayed.
It is possible to drag the window and different scale may be selected by right clicking inside
the window. The window is closed by double clicking inside or selecting the menu
Close
.
Ú
Note:
This feature is available on vector charts only.
MK Radar kit
Components
MK PC Radar kit includes hardware and software components.
Hardware, software, and set up are described in the
Radar Kit MK6 Installation manual
delivered together with the PC Radar Kit.
Software components includes the following applications:
•
Extractor/Tracker (VarpPCI.exe).
•
Sensor Monitor (Sensor Monitor.exe).
•
ETS Agent (ETSAgent.exe).
•
PCI Board Adjustment (SetupETS.exe).
•
Remote PCI Board Adjustment (RemoteSetupETS.exe).
•
Oscilloscope (Oscilloscope.exe).
•
MARIS ARPA-2000 (ARPA2000.exe).
Ú
Note:
MARIS PC Radar Kit provides the ability of combining Radar operations with the
ECDIS and is fully approved to IEC 61174 for overlay function. The Radar function
ARPA2000 has not been tested.
The Sensor Monitor processes the navigational information from ship’s sensors and sends it
to Extractor/Tracker. In case if Extractor/Tracker does not react on change of heading check
SMonitor.ini file.
Radar overlay
The PC Radar kit set the radar picture as a layer on top of the chart and automatically tracks
the radar targets.
130
Radar
| ECDIS900 Operator Manual