SINAMICS DCP
List Manual (LH21), 05/2016
179
2 Parameters
2.2 List of parameters
Description:
Sets the offset (DC component) of the signal to be generated for the function generator.
Dependency:
Units are dependent on p4810.
If p4810 = 1, 2, 4: The offset is referred to p2002 (reference current).
If p4810 = 3, 5: The offset is referred to p2000 (reference speed).
If p4810 = 2: In order to avoid the undesirable effects of play (backlash), the offset does not act on the current
setpoint, but instead on the speed setpoint.
Description:
Sets the ramp-up time to the offset for the function generator.
Description:
Sets the lower limit for the function generator.
Dependency:
For p4810 = 2 the limit only applies to the current setpoint, but not the speed setpoint (offset).
Description:
Sets the upper limit for the function generator.
Dependency:
For p4810 = 2 the limit only applies to the current setpoint, but not the speed setpoint (offset).
Description:
Sets the time slice cycle in which the function generator is called.
Description:
Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
p4826
Function generator offset / FG offset
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-1600.00 [%]
1600.00 [%]
0.00 [%]
p4827
Function generator ramp-up time to offset / FG ramp-up offset
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
0.00 [ms]
100000.00 [ms]
32.00 [ms]
p4828
Function generator lower limit / FG lower limit
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-10000.00 [%]
0.00 [%]
-100.00 [%]
p4829
Function generator upper limit / FG upper limit
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
0.00 [%]
10000.00 [%]
100.00 [%]
p4830
Function generator time slice cycle / FG time slice
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
0.03125 [ms]
2.00000 [ms]
0.12500 [ms]
p4831
Function generator amplitude scaling / FG amplitude scal
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
0.00000 [%]
200.00000 [%]
100.00000 [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...