2 Parameters
2.2 List of parameters
SINAMICS DCP
290
List Manual (LH21), 05/2016
Description:
Display and connector output for the correction current controller output.
Description:
Setting to activate the external current actual value
Value:
0:
Not activated
1:
Activated
Description:
Sets the signal source for the external current actual value.
Description:
Sets the integrating time for correction current controller.
Description:
Sets the limiting for correction current controller.
Description:
Display and connector output for the reactor current setpoint after dynamic voltage limiting.
Description:
Display and connector output for the reactor current setpoint of the main current controller.
r55151
CO: Correction current controller output / Corr_ctrl outp
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6806
Min Max
Factory
setting
- [%]
- [%]
- [%]
p55155
Current actual value external activation / I_act val ext act
DCP_CTRL
Can be changed:
T
Access level:
3
Data type:
Integer16
Func. diagram:
6806
Min Max
Factory
setting
0 1
0
p55156
CI: Current actual value external signal source / I_act ext s_src
DCP_CTRL
Can be changed:
T
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Func. diagram:
6806
Min Max
Factory
setting
- -
0
p55160
Correction current controller integrating time / Corr_ctrl t_int
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6806
Min Max
Factory
setting
1 [ms]
5000 [ms]
1000 [ms]
p55161
Correction current controller limiting / Corr_ctrl lim
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6806
Min Max
Factory
setting
0.000 [%]
50.000 [%]
10.000 [%]
r55170
CO: Limiting the reactor current setpoint after U dyn / Lim I_ re_sp U dyn
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6817
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55172
CO: Main current controller reactor current setpoint / Mn ctr I_react_set
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...