2 Parameters
2.2 List of parameters
SINAMICS DCP
270
List Manual (LH21), 05/2016
Description:
Display and connector output for the "Wire break" signal in the case of the CUD analog inputs.
Dependency:
Refer to: F60046, F60047
Note:
AI: Analog Input
Description:
Display and BICO output for the state of the monitoring of the external temperature sensor (terminal X177.53-55).
Description:
Display and BICO output for fixed bit 0 ... 7.
Dependency:
Refer to: p50421, p50422, p50423, p50424, p50425, p50426, p50427, p50428
Description:
Display and BICO output for the state of the telegram monitoring for the parallel interface.
r53030.0...1
CO/BO: CUD analog inputs wire break signal / CUD AI wire brk
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
2075, 2080
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
AI "Main setpoint" wire break monitoring
responded
Yes
No
2075
01
AI 1 (X177.27/28) wire break monitoring
responded
Yes
No
2080
r53130.0...1
CO/BO: Temperature monitoring external state / Temp_monit state
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
8030
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
External temperature alarm
Yes
No
8030
01
External temperature fault
Yes
No
8030
r53230.0...7
CO/BO: Fixed bit display / Fix bit displ
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
3100
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Fixed bit 0 (p50421)
High
Low
-
01
Fixed bit 1 (p50422)
High
Low
-
02
Fixed bit 2 (p50423)
High
Low
-
03
Fixed bit 3 (p50424)
High
Low
-
04
Fixed bit 4 (p50425)
High
Low
-
05
Fixed bit 5 (p50426)
High
Low
-
06
Fixed bit 6 (p50427)
High
Low
-
07
Fixed bit 7 (p50428)
High
Low
-
r53310.0...3
CO/BO: Parallel interface telegram monitoring state / Par_IF mon state
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
9350
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Telegram monitoring timeout - continuous
signal
Yes
No
9350
01
Telegram monitoring timeout - pulse
Yes
No
9350
02
OFF1 from master
1
0
9350
03
Pulse enable from the master
1
0
9350
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...