SINAMICS DCP
List Manual (LH21), 05/2016
147
2 Parameters
2.2 List of parameters
Dependency:
The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
Description:
Sets the setpoint for the input value in simulation mode of the analog inputs of Terminal Module 31 (TM31).
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency:
The simulation of an analog input is selected using p4097.
If AI x is parameterized as voltage input (p4056), then the setpoint is a voltage in V.
If AI x is parameterized as current input (p4056), then the setpoint is a current in mA.
Refer to: p4056, p4097
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
Description:
Sets the sampling time for the inputs and outputs of Terminal Module 15 (TM15).
Dependency:
The parameter can only be modified for p0009 = 3, 29.
The following applies for the sampling time:
The sampling times at a DRIVE-CLiQ line must be integral multiples of one another.
The sampling times of this TM must be an integral multiple of a servo or vector drive that exists in the system.
The minimum permissible sampling time is 125 µs.
Refer to: p0009, r0110, r0111
Note:
The changed sampling time is immediately effective after a completed sub-boot (p0009 -> 0).
Parameter p4099[0] must never be equal to zero.
Description:
Sets the sampling time for the inputs and outputs of Terminal Module 31 (TM31).
Index:
[0] = Digital inputs/outputs (DI/DO)
[1] = Analog inputs (AI)
[2] = Analog outputs (AO)
Dependency:
The parameter can only be modified for p0009 = 3, 29.
The following applies for the sampling time:
The sampling times at a DRIVE-CLiQ line must be integral multiples of one another.
The sampling times of this TM must be an integral multiple of a servo or vector drive that exists in the system.
The minimum permissible sampling time is 125 µs.
The sampling times entered in index 0 (digital inputs/outputs) and index 2 (analog outputs) must always be greater
than or equal to the sampling time in index 1 (analog inputs).
Refer to: p0009, r0110, r0111
Notice:
The sampling times entered in index 0 (digital inputs/outputs) and index 2 (analog outputs) must always be greater
than or equal to the sampling time in index 1 (analog inputs).
p4098[0...1]
TM31 analog inputs simulation mode setpoint / TM31 AI sim setp
TM31
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
9566, 9568
Min Max
Factory
setting
-20.000 20.000
0.000
p4099
TM15DI/DO inputs/outputs sampling time / TM15D I/O t_sampl
TM15DI_DO
Can be changed:
C1(3)
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
9399, 9400
Min Max
Factory
setting
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
p4099[0...2]
TM31 inputs/outputs sampling time / TM31 I/O t_sample
TM31
Can be changed:
C1(3)
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
9549, 9550
Min Max
Factory
setting
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...