SINAMICS DCP
List Manual (LH21), 05/2016
99
2 Parameters
2.2 List of parameters
Description:
Sets the first signal source to acknowledge faults.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
Description:
Sets the second signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
Description:
Sets the second signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
Description:
Sets the third signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
Description:
Sets the third signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
Description:
Sets the signal source for external fault 1.
Dependency:
Refer to: F07860
Note:
An external fault is triggered with a 1/0 signal.
If this fault is output at the Control Unit, then it is transferred to all existing drive objects.
p2103[0...n]
BI: 1. Acknowledge faults / 1. Acknowledge
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
2546
Min Max
Factory
setting
- -
0
p2104
BI: 2. Acknowledge faults / 2. Acknowledge
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
-
Min Max
Factory
setting
- -
0
p2104[0...n]
BI: 2. Acknowledge faults / 2. Acknowledge
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
2546
Min Max
Factory
setting
- -
0
p2105
BI: 3. Acknowledge faults / 3. Acknowledge
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
-
Min Max
Factory
setting
- -
0
p2105[0...n]
BI: 3. Acknowledge faults / 3. Acknowledge
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
2546
Min Max
Factory
setting
- -
0
p2106
BI: External fault 1 / External fault 1
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
-
Min Max
Factory
setting
- -
1
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...