2 Parameters
2.2 List of parameters
SINAMICS DCP
272
List Manual (LH21), 05/2016
Description:
Sets the current stage of the MPP tracker.
The MPP tracker changes the current setpoint in these stages in order to identify the point with the maximum power.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the current reduction factor of the MPP tracker.
Factor by which the MPP tracker reduces the current setpoint when the lower voltage limit is reached.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the energy flow direction for the MPP tracker.
Value = -1:
Energy flows from side 2 to side 1.
The MPP tracker specifies a negative current.
Value = +1:
Energy flows from side 1 to side 2.
The MPP tracker specifies a positive current.
Value:
-1:
Negative (side 2 to side 1)
1:
Positive (side 1 to side 2)
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the signal source for the actual power of the MPP tracker.
Dependency:
Refer to: p54011, r54015
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the time constant for smoothing the actual power value.
Dependency:
Refer to: p54010, r54015
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
p54006
MPP tracker current stage / MPPT I_stage
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
0.10 [%]
100.00 [%]
1.00 [%]
p54007
MPP tracker current reduction factor / MPPT I_reduce
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
0.10 [%]
100.00 [%]
90.00 [%]
p54009
MPP tracker energy flow direction / MPPT energy direct
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
Integer16
Func. diagram:
6700
Min Max
Factory
setting
-1 1
-1
p54010
CI: MPP tracker actual power signal source / MPPT act P s_src
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
- -
55540[0]
p54011
MPP tracker actual power smoothing time constant / MPPT act P T
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
0.00 [s]
100.00 [s]
0.05 [s]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...