SIN
A
MICS
DCP
List Manual (LH
21)
, 05
/2016
32
9
3
F
un
ction dia
g
ra
ms
3.4
P
ROFIdr
ive
F
ig.
3
-14
24
10 – PROF
IBU
S
(PB)/PROFINE
T
(PN)/USS, ad
dresses and
d
iagn
osti
cs
fp_2410_89.vsd
1
2
3
4
5
6
7
8
- 2410 -
SINAMICS DCP
03.06.2014
v 1.2
DO: CU_DCP;DCP_CTRL
- PROFIBUS (PB) / PROFINET (PN) / USS, addresses and diagnostics
Function diagram
t
Q
Q
S
R
R
+
0
T
0
T
+
+
+
[1020.7]
PROFIdrive sampling time
PB status
r02054
PB diag standard
r02055[0...2]
A01900
PB/PN: ConfigTelegr error
Set PROFIBUS address
POWER ON
PROFINET address
Telegram failure from master
A01920
PB: Interrupt cyc conn
Monitoring is only performed once
at least one "valid" cyclic telegram has been
received for the first time. "Valid" means:
Master is in operation and user data is transferred.
<3>
IF1 PD fault delay
0...100 [s]
p02044 (1)
Cyclic
telegrams
from the master
Current
PROFIBUS
address
Diagnostic parameters
PB suppl t_monit
p02047
PN Name of Station
r61000[0...239]
PN IP of Station
r61001[0...3]
<3>
<3>
PB address
1...126
p00918 (126)
r02043.01
Sync op act
r02043.01
IF1 PD PZD state
Memory
SET
r02043.00
Set_failure
r02043.00
IF1 PD PZD state
F01910
Fieldbus: setp timeout
Field bus error
r02029[0...7]
USS settings
Field bus baud
p02020
Field bus address
p02021
Field bus USS PZD
p02022
Field bus USS PKW
p02023
Fieldbus USS DO_no
p02035
USS
USS
protocol
PPI
protocol
Parameter
management
1
0
3
1
0
2
PZD
IF1
Field bus protocol
p02030
Field bus protocol
p02030
X1400
X126
X178
PZD IF HW assign
p08839[0]
<1>
Monitoring and diagnostics
Process data transmission
CBE20
PROFIBUS
PROFINET
PROFINET
PROFIBUS
protocol
Ethernet
interface
PROFIBUS
connection
AOP30/USS
interface
Position 99:
When CBE20 is inserted: Switch position = 2
When CBE20 is not inserted: Switch position = 1
<1>
See:
FP2460
FP2470
FP2472
FP2481
FP2483
1
0
3
+
X179
+
RS 485
RS 232
<4>
<4>
<4> Only one of the two interfaces -
RS 485 (X178-3, 4) or RS 232 (X179-3, 4) - may be used.
DCP_CTRL
1
0
2
PZD IF HW assign
p08839[1]
<2>
+
+
PZD
IF2
see:
FP2485
FP2487
FP2489
Position 99:
Switch position = 0
<2>
<5> Bus termination can be switched on/off with p50820
<5>
<6>
<6> Not with CPU stop
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...