SINAMICS DCP
List Manual (LH21), 05/2016
227
2 Parameters
2.2 List of parameters
Description:
Displays the signal source list (Binector Output/Connector Output, BO/CO) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9491, p9493
Notice:
A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description:
Setting to reset the BICO interconnections to other drives.
Each interconnection can be individually reset.
Value:
0:
Set connection to 0
1:
Set connection to 1 (100 %)
2:
Set connection to factory setting
15:
Finished
Dependency:
Refer to: r9490, r9491, r9492
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description:
Sets the behavior for BICO interconnections to drive objects that are either not capable of operation or have been
deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Value:
0:
Inactive
1:
Save interconnections
2:
Save interconnections and establish the factory setting
Dependency:
Refer to: p9496, p9497, p9498, p9499
Refer to: A01318, A01507
Note:
For p9495 = 0, the following applies:
- the number of interconnections is zero (p9497 = 0).
For p9495 not equal to 0, the following applies:
- the BI/CI parameters involved are listed in p9498[0...29] (signal sink).
- the associated BO/CO parameters are listed in p9499[0...29] (signal source).
r9492[0...9]
BO/CO of BICO interconnections to other drives / BO/CO to drive
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
p9493[0...9]
Reset BICO interconnections to other drives / Reset BICO to drv
All objects
Can be changed:
T
Access level:
3
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 15
15
p9495
BICO behavior for de-activated drive objects / Behav for deact DO
All objects
Can be changed:
T
Access level:
3
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 2
0
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...