
2 Parameters
2.2 List of parameters
SINAMICS DCP
250
List Manual (LH21), 05/2016
Description:
Sets the offset for the "main actual value" (XT1.103/104).
Notice:
This analog input cannot be externally accessed. It is reserved for subsequent use.
Note:
AI: Analog Input
Description:
Sets the mode for signal processing for the "main actual value" analog input (XT1.103/104).
Value:
0:
Signal not influenced
1:
Signal absolute value generation
2:
Signal inverted
3:
Signal absolute value generation inverted
Notice:
This analog input cannot be externally accessed. It is reserved for subsequent use.
Note:
AI: Analog Input
Description:
Sets the signal source for inverting the signal from the "main actual value" analog input (XT1.103/104).
0 signal: no inversion
1 signal: inversion
Notice:
This analog input cannot be externally accessed. It is reserved for subsequent use.
Note:
AI: Analog Input
Description:
Sets the time constant for smoothing the signal from the "main actual value" analog input (XT1.103/104).
Notice:
This analog input cannot be externally accessed. It is reserved for subsequent use.
Note:
AI: Analog Input
Description:
Sets the signal source for enabling the analog input for the "main actual value (XT1.103/104).
Notice:
This analog input cannot be externally accessed. It is reserved for subsequent use.
Note:
AI: Analog Input
p50742
Analog input main actual value offset / AI m act offs
DCP_CTRL
Can be changed:
U, T
Access level:
4
Data type:
FloatingPoint32
Func. diagram:
2075
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
0.00 [%]
p50743
Analog input main actual value signal processing / AI m act sig
DCP_CTRL
Can be changed:
T
Access level:
4
Data type:
Integer16
Func. diagram:
2075
Min Max
Factory
setting
0 3
0
p50744
BI: Analog input main actual value inversion / AI m act inv
DCP_CTRL
Can be changed:
T
Access level:
4
Data type:
Unsigned32 / Binary
Func. diagram:
2075
Min Max
Factory
setting
- -
0
p50745
Analog input main actual value smoothing time constant / AI m act T
DCP_CTRL
Can be changed:
U, T
Access level:
4
Data type:
FloatingPoint32
Func. diagram:
2075
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50746
BI: Signal source to enable analog input main actual value / AI m act ena s_src
DCP_CTRL
Can be changed:
T
Access level:
4
Data type:
Unsigned32 / Binary
Func. diagram:
2075
Min Max
Factory
setting
- -
1
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...