2 Parameters
2.2 List of parameters
SINAMICS DCP
228
List Manual (LH21), 05/2016
Description:
Sets the behavior when activating BICO interconnections to drive objects that are either not capable of operation or
have been deactivated.
Value:
0:
Inactive
1:
Restore the interconnections from the list
2:
Delete the interconnections from the list
Dependency:
Refer to: p9495, p9497, p9498, p9499
Refer to: A01318, A01507
Note:
The BI/CI parameters involved are listed in p9498[0...29] (signal sink).
The associated BO/CO parameters are listed in p9499[0...29] (signal source).
After p9496 = 1, 2 the following applies:
- p9497 = 0
- p9496 = 0
Description:
Displays the number of saved BICO interconnections to drive objects that are either not capable of operation or have
been deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Dependency:
Refer to: p9495, p9496, p9498, p9499
Refer to: A01318, A01507
Description:
Displays the saved BI/CI parameters (signal sink), whose source is located on drive objects that are either not
capable of operation or have been deactivated.
Dependency:
Refer to: p9495, p9496, p9497, p9499
Refer to: A01318, A01507
Note:
A BICO interconnection (signal sink, signal source) is displayed in the same index of p9498 and p9499.
Description:
Displays the saved BO/CO parameters (signal source), which are located on drive objects that are either not capable
of operation or have been deactivated.
Dependency:
Refer to: p9495, p9496, p9497, p9498
Refer to: A01318, A01507
Note:
A BICO interconnection (signal sink, signal source) is displayed in the same index of p9498 and p9499.
p9496
BICO behavior when activating drive objects / Behav when act DO
All objects
Can be changed:
T
Access level:
3
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 2
0
p9497
BICO interconnections to de-activated drive objects number / Interconn obj qty
All objects
Can be changed:
T
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
p9498[0...29]
BICO BI/CI parameters to de-activated drive objects / BI/CI to deact obj
All objects
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
0
p9499[0...29]
BICO BO/CO parameters to de-activated drive objects / BO/CO to deact obj
All objects
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
0
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...