SINAMICS DCP
03.06.2014
v 1.2
DO: All Objects
- Explanation of the symbols (part 2)
Function diagram
x
y
-1
x
y
x
2
x
1
y
S Q
R Q
S
y
x
1
0
0
1
y
x
S
LU
LL
MLL
MLU
x
y
SET
S & H
x
y
dx
dt
x
y
0
1
S
H
y
x
0
1
H
S
y
x
=1
x
1
y
x
2
1
0
1
&
1
The factory setting for the switch position
is displayed (in this case, the delivery
state is switch position 1).
Monitoring
Positioning in sheet at bottom right.
Axxxxx
or
Fxxxxx
pxxxx
S = Input for setting
R = Input for resetting
Q = Non-inverted output
Q = Inverted output
y = 1 if x1 != x2.
y = -x
y = |x|
y =
Output y = logical "1" if output signal x > 0,
i.e. if it is positive.
x
1
x
2
y =
dx
dt
Outputs a logical "1" at output y if x < S.
Outputs a logical "1" at output y if x > S.
Outputs a logical "1" at output y if x < S.
If x >= S + H, y returns to 0.
Outputs a logical "1" at output y if x > S.
If x <= S - H, y returns to 0.
x is limited to the upper limit value LU and the
lower limit value LL and is output at output y.
The binary signals MLU and MLL have the
value "1" if upper or lower limiting is active.
Sample and hold element.
y = x if SET = 1
(no retentive memory during
POWER OFF)
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...