2 Parameters
2.2 List of parameters
SINAMICS DCP
156
List Manual (LH21), 05/2016
Notice:
When forming groups, it must be ensured that in one particular group, only temperature channels with the following
sensor types are included:
- "KTY84", "PT100", "PT1000" (p4100[0...11] = 2, 5, 6), real temperature actual value
or alternatively
- "PTC thermistor", "bimetallic NC contact" (p4100[0...11] = 1, 4), fictitious temperature actual value (-50 °C, 250 °C)
If these sensor types are combined within one group, then the calculated values for maximum, minimum and average
value will be falsified.
Note:
Active and inactive temperature channels can be included in one group. However, when calculating the values
(r4112, r4113, r4114) only the active temperature channels with valid actual value are taken into account
(r4105[0...11] not equal to -300 °C).
Description:
Display and connector output for the maximum value of each group for the Terminal Module 150 (TM150).
This value is calculated from the actual temperature values (r4105[0...11]) of each group.
Recommendation:
The following connector inputs can use these connector outputs for interconnection:
- CI: p0603
- CI: p0608[0...3]
- CI: p0609[0...3]
- CI: p2051
Index:
[0] = Group 0
[1] = Group 1
[2] = Group 2
Dependency:
Refer to: r4105, p4111, r4113, r4114
Description:
Display and connector output for the minimum value of each group for the Terminal Module 150 (TM150).
This value is calculated from the actual temperature values (r4105[0...11]) of each group.
Recommendation:
The following connector inputs can use these connector outputs for interconnection:
- CI: p0603
- CI: p0608[0...3]
- CI: p0609[0...3]
- CI: p2051
Index:
[0] = Group 0
[1] = Group 1
[2] = Group 2
Dependency:
Refer to: r4105, p4111, r4112, r4114
Description:
Display and connector output for the average value of each group for the Terminal Module 150 (TM150).
This value is calculated from the actual temperature values (r4105[0...11]) of each group.
r4112[0...2]
CO: TM150 group temperature actual value maximum value / TM150 grp temp max
TM150
Can be changed:
-
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
9625
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r4113[0...2]
CO: TM150 group temperature actual value minimum value / TM150 grp temp min
TM150
Can be changed:
-
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
9625
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r4114[0...2]
CO: TM150 group temperature average actual value / TM150 grp temp av
TM150
Can be changed:
-
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
9625
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...