2 Parameters
2.2 List of parameters
SINAMICS DCP
30
List Manual (LH21), 05/2016
Description:
Runs the corresponding macro files.
The selected macro file must be available on the memory card/device memory.
Example:
p0015 = 6 --> the macro file PM000006.ACX is run.
Dependency:
Refer to: p0700, p1000, p1500, r8570
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
When executing a specific macro, the corresponding programmed settings are made and become active.
No errors were issued during quick commissioning (p3900 = 1) when writing to parameters of the QUICK_IBN group!
Note:
The macros in the specified directory are displayed in r8570. r8570 is not in the expert list of the commissioning
software.
Macros available as standard are described in the technical documentation of the particular product.
Description:
Setting for activating/de-activating the user-defined list for the Basic Operator Panel (BOP).
If p0016 = 1, then it is only possible to access parameters in the parameter list (p0013).
Value:
0:
BOP user-defined list de-activated
1:
BOP user-defined list activated
Dependency:
Refer to: p0011, p0012, p0013
Note:
The user-defined list can only be de-activated with p0011 = p0012
Description:
Displays the basic firmware version of the Control Unit.
The version of existing firmware on the device memory is displayed in r7844.
Dependency:
Refer to: r0158, r0197, r0198, r7844
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Displays the control word for the Basic Operator Panel (BOP).
p0015
Macro drive object / Macro DO
DCP_CTRL, TM150,
TM15DI_DO, TM31
Can be changed:
C2(1)
Access level:
1
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
0 999999
0
p0016
Activate BOP user-defined list / BOP user list act
CU_DCP
Can be changed:
C1, U, T
Access level:
3
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 1
0
r0018
Control Unit basic firmware version / CU Basic FW Vers
CU_DCP
Can be changed:
-
Access level:
1
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
-
r0019.0...14
CO/BO: Control word BOP / STW BOP
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
9912
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
ON / OFF (OFF1)
ON
OFF (OFF1)
-
01
No coast-down / coast-down (OFF2)
No coast down
Coast down (OFF2)
-
02
No Quick Stop / Quick Stop (OFF3)
No Quick Stop
Quick Stop (OFF3)
-
07
Acknowledge fault (0 -> 1)
Yes
No
-
13
Motorized potentiometer raise
Yes
No
-
14
Motorized potentiometer lower
Yes
No
-
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...