2 Parameters
2.2 List of parameters
SINAMICS DCP
180
List Manual (LH21), 05/2016
Description:
Sets the scaling for the amplitude of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description:
Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description:
Displays the output signal for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Dependency:
Refer to: p4810
Note:
The signals are only output in the "free measurement function" operating mode (p4810 = 6)
Description:
Sets the scaling of the output signals for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Note:
The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
Description:
Sets the number of cycles of a multiple trace.
p4832[0...2]
Function generator amplitude scaling / FG amplitude scal
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-340.28235E36 [%]
340.28235E36 [%]
100.00000 [%]
p4833[0...2]
Function generator offset scaling / FG offset scal
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-340.28235E36 [%]
340.28235E36 [%]
100.00000 [%]
r4834[0...4]
CO: Function generator free measurement output signal / FG fr MeasFct outp
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
p4835[0...4]
Function generator free measurement function scaling / FG fr MeasFct scal
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-200.00000 [%]
200.00000 [%]
100.00000 [%]
p4840[0...1]
MTrace cycle number setting / Cycle number
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...