2 Parameters
2.2 List of parameters
SINAMICS DCP
302
List Manual (LH21), 05/2016
Description:
Display and connector output for the reactor current of power unit 3.
Dependency:
Refer to: r55510
Description:
Sets the internal resistance of the voltage source connected at side 1.
The setting value for this parameter is referred to the rated device quantities (rated voltage, rated current)
p55515 = Ri * I_rated/U_rated
Ri:
Internal resistance of the voltage source connected at side 1.
Description:
Sets the internal resistance of the voltage source connected at side 2.
The setting value for this parameter is referred to the rated device quantities (rated voltage, rated current)
p55516 = Ri * I_rated/U_rated
Ri:
Internal resistance of the voltage source connected at side 2.
Description:
Sets the smoothing time constant in the voltage actual value channel.
Index:
[0] = Side 1
[1] = Side 2
Description:
Display and connector output for the sum of the averaged reactor currents.
The value is the sum of r55521, r55522 and r55523.
Dependency:
Refer to: r55521, r55522
r55513
CO: Actual value reactor current power unit 3 / ActVal I_react PU3
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
- [%]
- [%]
- [%]
p55515
Resistance inner side 1 / R inner S1
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
0.00 [%]
20.00 [%]
0.00 [%]
p55516
Resistance inner side 2 / R inner S2
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
0.00 [%]
20.00 [%]
0.00 [%]
p55518[0...1]
Voltage actual value smoothing time constant / U_act T
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
0.00 [ms]
1000.00 [ms]
100.00 [ms]
r55520
CO: Actual value reactor current sum averaged / ActVal I_re SumAvg
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...