SINAMICS DCP
List Manual (LH21), 05/2016
293
2 Parameters
2.2 List of parameters
Description:
Sets the limiting for main current controller.
Description:
Set the multiplier to evaluate the precontrol for the main current controller.
Description:
Displays the current until the current in the individual power units is discontinuous
Description:
Display and connector output for the control angle of power unit 1.
Description:
Display and connector output for the control angle of power units 2 and 3.
Index 0:
Control angle of power unit 2.
Index 1:
Control angle of power unit 3.
Description:
Display and connector output for the outputs of the differential current controller.
Index 0:
Correction value to symmetrize power units 1 and 2.
Index 1:
Correction value to symmetrize power units 1 and 3.
p55228
Main current controller limiting / Main ctrl limit
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
1.0 [%]
200.0 [%]
200.0 [%]
p55230
Main current controller precontrol multiplier / Mn ctr prctr fact
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
0.0 [%]
100.0 [%]
98.0 [%]
r55235
Discontinuous limit / Discontinuous lim
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
- [A]
- [A]
- [A]
r55250
CO: Power unit 1 control angle / PU1 ctrl_angle
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6825
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55251[0...1]
CO: Power units 2 and 3 control angle / PU 2 3 ctrl_angle
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6825
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55252[0...1]
CO: Differential current controller output / I_diff_ctrl_outp
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6825
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...