SINAMICS DCP
List Manual (LH21), 05/2016
113
2 Parameters
2.2 List of parameters
Description:
Display and BICO output for the third status word of the monitoring functions.
Description:
Connector output of the reference quantity for temperatures.
All temperatures specified as relative value are referred to this reference quantity.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
This parameter has the unit degree Celsius.
Note:
This BICO parameter provides the numerical value of the reference quantity for the temperature as a connector
output for interconnection with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this
connector output in DCC. This BICO parameter is not suitable for interconnecting for cyclic communication.
Description:
Setting and connector output for a fixed percentage value.
Dependency:
Refer to: p2901, r2902, p2930
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can be used to interconnect a scaling function (e.g. scaling of the main setpoint)
Description:
Setting and connector output for a fixed percentage value.
Dependency:
Refer to: p2900, p2930
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can be used to interconnect a scaling function (e.g. scaling of the supplementary setpoint)
Description:
Display and connector output for frequently used percentage values.
Index:
[0] = Fixed value +0 %
[1] = Fixed value +5 %
[2] = Fixed value +10 %
[3] = Fixed value +20 %
r2199.1
CO/BO: Status word monitoring 3 / ZSW monitor 3
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
2537
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
01
f or n comparison value reached or
exceeded
Yes
No
8010
r2706
CO: Reference temp / Reference temp
TM150, TM31
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- -
-
p2900[0...n]
CO: Fixed value 1 [%] / Fixed value 1 [%]
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-10000.00 [%]
10000.00 [%]
0.00 [%]
p2901[0...n]
CO: Fixed value 2 [%] / Fixed value 2 [%]
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-10000.00 [%]
10000.00 [%]
0.00 [%]
r2902[0...14]
CO: Fixed values [%] / Fixed values [%]
DCP_CTRL
Can be changed:
-
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...