2 Parameters
2.2 List of parameters
SINAMICS DCP
188
List Manual (LH21), 05/2016
r7843[19] = 0 dec --> ASCII characters = " " --> serial number, character 20
r7843[20] = 0 dec
Serial number = 111923E
Description:
Displays the version of the firmware stored on the device memory.
Index:
[0] = Internal
[1] = External
[2] = Parameter backup
Note:
Re index 0:
Displays the internal firmware version (e.g. 01402315).
This firmware version is the version of the device memory and not the CU firmware (r0018), however, normally they
have the same versions.
Re index 1:
Displays the external firmware version (e.g. 01040000 -> 1.4).
Re index 2:
Displays the internal CU firmware version (r0018) of the parameter backup.
With this CU firmware version, the parameter backup was saved, which was used when powering up.
Description:
Displays whether, for an activated drive object, all activated topology components are available or not (or whether
these can be addressed).
0: Drive object not ready for operation
1: Drive object ready for operation
Description:
Sets the mode for the sub-boot.
Value:
0:
Sub-boot manual
1:
Sub-boot automatic
Note:
For p7857 = 0 (manual sub-boot) the following applies:
The parameter should be set to 1 to start the sub-boot.
Description:
Displays the configuration changes on the drive object.
Index:
[0] = Sum of the following indices
[1] = p0010, p0107, p0108
[2] = Drive object name (p0199)
[3] = Structure-relevant parameters (e.g. p0180)
[4] = BICO interconnections
r7844[0...2]
Device memory firmware version / Dev_mem FW
CU_DCP
Can be changed:
-
Access level:
1
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r7850[0...n]
Drive object operational/not operational / DO ready for oper
CU_DCP
Can be changed:
-
Access level:
4
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
-32786 32767
-
p7857
Sub-boot mode / Sub-boot mode
TM150, TM15DI_DO,
TM31
Can be changed:
U, T
Access level:
4
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 1
1
r7871[0...15]
Configuration changes drive object / Config_chng DO
TM150, TM15DI_DO,
TM31
Can be changed:
-
Access level:
4
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...